Permit Details

Permit Search

Permit

New Residential Construction

283 SW OTTER LN
FORT WHITE, FL 32038

Permit #
000053722
Application #
70563
Status Completed
  1. Submitted Jul 1, 2025
  2. Issued Jul 31, 2025
  3. Expires Dec 22, 2026
  4. Completed Jun 25, 2026

Property

Parcel #
10024-077
Owner
Udelhofen Kurtis S & Elizabeth Dominguez Revocable Trust Utd November 20, 2018,
Acres
3.14
Subdivision
Sassafras Acres
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0532C
This is the construction of a
Single Family Dwelling
Stories
1
Heated Area (Sqft)
1549
Total Area (Sqft)
3283
Building Height
21
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0555
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Pre-submittal Review Notes
  3. Point Review - Pre-submittal Review Notes
  4. Point Review - Pre-submittal Review Notes
  5. Point Review - Ready for applicant submittal
  6. Application submitted by applicant.
  7. Application submitted by applicant.
  8. Point Review - Reviewed
  9. Zoning Review - Reviewed
  10. Plan Review - Building Approved
  11. Plan Review - Electrical Approved
  12. Plan Review - Mechanical Approved
  13. Plan Review - Plumbing Approved
  14. Plan Review - Fuel/Gas Approved
  15. Plan Review - Reviewed
  16. Final Review - Reviewed
  17. Final Review - Payment Needed
  18. Permit Issued

Contractors

  • Cecilio Garcia

    Kg Construction Llc

    License
    CRC1329233
    Title
    Cert Residential
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Donald Davis

    High Springs Electric Inc

    License
    EC0002306
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Donald R Davis

    High Springs Electric Inc

    License
    CAC1815367
    Title
    Class B A/c
    Role
    Subcontractor
  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tabitha M Sibel

    Rjh Construction

    License
    CCC1331967
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Aug 1, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    System Under Test

    Inspected by Anthony Aslan

  2. Aug 11, 2025

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  3. Aug 11, 2025

    Passed: Engineering - Setbacks

    Appears Within Setbacks

    Inspected by Anthony Aslan

  4. Sep 2, 2025

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  5. Sep 2, 2025

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  6. Oct 28, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  7. Oct 28, 2025

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  8. Oct 28, 2025

    Failed: Building - Framing

    Nails Missing Garage Htt Strap no Doors Installed windows In Living Room Not Safety Glass, Seal Height Low

    Inspected by Anthony Aslan

  9. Oct 28, 2025

    Failed: Mechanical - Rough In

    No Gaskets On Boots

    Inspected by Anthony Aslan

  10. Oct 28, 2025

    Cancelled: Building - Strapping

    Inspected by Aaslan

  11. Oct 28, 2025

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Anthony Aslan

  12. Oct 28, 2025

    Cancelled: Building - Window Attachment

    Inspected by Aaslan

  13. Dec 2, 2025

    Passed: Building - Framing

    Inspected by Christian Allen

  14. Dec 2, 2025

    Passed: Mechanical - Rough In

    Inspected by Christian Allen

  15. Dec 12, 2025

    Passed: Building - Insulation

    Inspected by Christian Allen

  16. May 15, 2026

    Passed: Electrical - Permanent Power

    Pending Septic Release

    Inspected by Christian Allen

  17. Jun 3, 2026

    Release to power company

    Rec'd Septic Final

    Inspected by Ewilliams

  18. Jun 3, 2026

    Septic Release Inspection

    Inspected by Health Dept

  19. Jun 25, 2026

    Passed: Building - Final

    *all Requirements Met To Release Co-- 6.25.26 Mg

    Inspected by Christian Allen

Documents