Permit Details

Permit Search

Permit

Storage Building

213 SW WASHINGTON AVE
FORT WHITE, FL 32038

Permit #
000053601
Application #
71631
Status Completed
  1. Submitted Jun 20, 2025
  2. Issued Jul 16, 2025
  3. Expires Feb 11, 2026
  4. Completed Aug 15, 2025

Property

Parcel #
01037-001
Owner
Bedenbaugh Alvin, Bedenbaugh Teri
Acres
0.96
Subdivision
Three Rivers Estates Unit 18
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Accessory Use
Finished floor requirement
Non-Habitable Structure
Fema map number
12023C0458C
Type of Structure
Storage Building
Commercial or Residential?
Residential
Total Area (Sqft)
2016
Septic# (00-0000) or (X00-000)
25-0517
Setbacks Front
30'
Setback Side 1
10'
Setback Side 2
10'
Setback Rear
10' (accessory)
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Storage
Occupancy Use Title
*NON-HABITABLE STRUCTURE
Dev Permit #
F023-
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Building Height
16'
Building Length
48'
Building Width
42'
Service Amps
200
Slab
None
Mechanical
No
Electrical
Yes
Plumbing
No

Status & Review History

  1. Application pending.
  2. Point Review - Pre-submittal Review Notes
  3. Point Review - Pre-submittal Review Notes
  4. Point Review - Pre-submittal Review Notes
  5. Point Review - Pre-submittal Review Notes
  6. Point Review - Pre-submittal Review Notes
  7. Point Review - Ready for applicant submittal
  8. Application submitted by applicant.
  9. Point Review - Printed-Online Application
  10. Point Review - Reviewed
  11. Zoning Review - Reviewed
  12. Plan Review - Documents Required
  13. Plan Review - Reviewed
  14. Final Review - Reviewed
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Failed to auto issue permit on credit card payment.
  18. Final Review - Complete

Contractors

This is an owner-builder project.

  • Donald Davis

    High Springs Electric Inc

    License
    EC0002306
    Title
    Electrical Contractor
    Role
    Subcontractor

Inspections

  1. Jul 2, 2025

    Septic Release Inspection

    Inspected by Health Dept

  2. Jul 22, 2025

    Passed: Building - Footer

    Inspected by Matt Forsyth

  3. Jul 22, 2025

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  4. Aug 14, 2025

    Passed: Electrical - Permanent Power

    Cannot Release Power Until Driveway Permit Has Final Inspection.

    Inspected by Matt Forsyth

  5. Aug 15, 2025

    Release to power company

    Driveway Was Verification Of Existing

    Inspected by Ewilliams

  6. Aug 15, 2025

    Passed: Building - Final

    No Dwelling On Property

    Inspected by Matt Forsyth