Permit Details

Permit Search

Permit

New Residential Construction

245 SW COLONY GLN
LAKE CITY, FL 32024

Permit #
000053462
Application #
71019
Status Completed
  1. Submitted May 15, 2025
  2. Issued Jun 25, 2025
  3. Expires Apr 21, 2026
  4. Completed Oct 27, 2025

Property

Parcel #
03761-142
Owner
Pizzagalli Bobbie S, Pizzagalli Theodore J
Acres
5.01
Subdivision
Meadowlands Phase 3
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
81.8'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0485C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2281
Total Area (Sqft)
2451
Building Height
15
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0296
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Zoning Review - Processing
  5. Zoning Review - Reviewed
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Plumbing Approved
  9. Plan Review - Mechanical Approved
  10. Plan Review - Electrical Approved
  11. Plan Review - Building Approved
  12. Plan Review - Reviewed
  13. Final Review - Documents Required
  14. Final Review - Documents Required
  15. Final Review - Corrections Needed
  16. Final Review - Corrections Needed
  17. Final Review - Payment Needed
  18. Final Review - Payment Needed
  19. Final Review - Payment Needed
  20. Final Review - Payment Needed
  21. Permit Issued
  22. Zoning Review - Documents Required

Contractors

  • Mark J Mashburn

    Americas Home Place Inc

    License
    CRC1330787
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance Expired.

  • Jeffrey T Crabtree

    Crabtree Plumbing,inc.

    License
    CFC032618
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Donald R Davis

    High Springs Electric Inc

    License
    CAC1815367
    Title
    Class B A/c
    Role
    Subcontractor
  • Donald Davis

    High Springs Electric Inc

    License
    EC0002306
    Title
    Electrical Contractor
    Role
    Subcontractor

Inspections

  1. Jul 21, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Reminder Will Need Compaction Test For Slab

    Inspected by Troy Crews

  2. Jul 31, 2025

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  3. Jul 31, 2025

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  4. Aug 8, 2025

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  5. Aug 8, 2025

    Release to power company

    Inspected by Troy Crews

  6. Aug 13, 2025

    Rescheduled 8/15/2025:Building - Ext Strapping/Wall Sheathing

    Inspected by Neonta Anderson

  7. Aug 13, 2025

    Rescheduled 8/15/2025:Building - Roof Decking

    Inspected by Neonta Anderson

  8. Aug 15, 2025

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  9. Aug 15, 2025

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  10. Aug 27, 2025

    Passed: Building - Framing

    Simpson Sdwc Screws Used For Headers And Truss Tie Down

    Inspected by Troy Crews

  11. Aug 27, 2025

    Passed: Building - Window Attachment

    All Factory Holes Have A Screw

    Inspected by Troy Crews

  12. Aug 27, 2025

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  13. Aug 27, 2025

    Passed: Electrical - 1st Underground Rough–In

    Second Roof In Wall Inspection

    Inspected by Troy Crews

  14. Aug 28, 2025

    Failed: Plumbing/Gas - 1st Underground Rough–In

    Plumbing Not Complete No Pressure On Water Lines Drain Line For Tub Not Complete

    Inspected by Troy Crews

  15. Aug 29, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Need Nail Guard On Dryer Vent Pipe

    Inspected by Anthony Aslan

  16. Sep 3, 2025

    Passed: Building - Insulation

    Inspected by Troy Crews

  17. Sep 5, 2025

    Septic Release Inspection

    Inspected by Health Dept

  18. Oct 6, 2025

    Passed: Electrical - Permanent Power

    Inspected by Gary Pitzer

  19. Oct 6, 2025

    Release to power company

    Inspected by Gary Pitzer

  20. Oct 21, 2025

    Failed: Building - Final

    Electric Outlets Are Not Complete In Island Cabinet

    Inspected by Gary Pitzer

  21. Oct 23, 2025

    Passed: Building - Final

    All Requirements Met To Release Co

    Inspected by Matt Forsyth

Documents