Permit Information

New Residential Construction Permit

Address 311 SW SILVER PALM DR
LAKE CITY, FL 32024
Parcel #: 02731-088
Acres:0.25
Owner:Adams Homes Of Northwest Florida, Inc,
Subdivision:Preserve At Laurel Lake Unit 1
Zoning:PRD
Flood Zone:X
District:3
Application #:70415
Permit #: 000053082
Related Permit:
Submitted:Wednesday, April 16, 2025
Issued:Tuesday, July 8, 2025
Expires:Thursday, September 4, 2025
Completed:Thursday, September 4, 2025
Status: Completed
Septic Release? Yes

Notes

*MFE = 117.3' PER ENGINEER LETTER, SURVEYOR TO CONFIRM FFE AND SETBACKS, ELEVATION CONFIRMATION RECEIVED @ 117.52', SETBACKS CONFIRMED *DRIVE FINAL REQUIRED PRIOR TO POWER RELEASE *CITY TAP INSPECTION REQUIRED PRIOR TO FINAL-- REQUEST THROUGH COUNTY
LAKE CITY UTLITY CUSTOMER SERVICE NOTES 05/01/25 The Utility Department approved the tap application for water and sewer services for this location. Locates must be obtained to ensure that the existing utility infrastructure is not damaged or obstructed.

Job Details

Elevation regulation Engineers Elevation Letter
Finished floor requirement 117.3'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1647
Total Area (Sqft) 2404
Building Height 19
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200

Review Notes

4/16/2025 Application pending.
4/16/2025 Application submitted by applicant.
4/16/2025 City of Lake City Utilities Notified.
4/21/2025 Point Review - Processing
4/25/2025 Plan Review - Plumbing Approved
4/25/2025 Plan Review - Mechanical Approved
4/25/2025 Plan Review - Electrical Approved
4/25/2025 Plan Review - Building Approved
4/25/2025 Plan Review - Reviewed
4/25/2025 Zoning Review - Processing
4/29/2025 Zoning Review - Reviewed
4/29/2025 Final Review - Corrections Needed
5/1/2025 Final Review - Payment Needed
5/9/2025 Final Review - Payment Needed
5/12/2025 Permit Issued
7/8/2025 Permit Reissued

Contractors

Name / Business License Title Role
William Adams
Adams Homes Of Northwest Florida Inc
CRC1330146 Cert. Residential Contractor
Shawn Reynolds
Ncf Electrical Services Llc
County License & State License & Liability Insurance & Workers Comp Expired.
EC13011927 Cert. Electrical Subcontractor
Derrick L Williams
D L Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
County License & State License & Workers Comp Expired.
CCC1330509 Cert. Roofing Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 5/14/2025
Passed: Building - Monolithic Slab Troy Crews 5/20/2025
Passed: Engineering - Setbacks I Surveyor To Confirm Setbacks Troy Crews 5/20/2025
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 6/27/2025
Passed: Building - Framing Troy Crews 6/27/2025
Passed: Building - Roof Decking Troy Crews 6/27/2025
Passed: Building - Strapping Put Straps On Back Porch Post At Top Troy Crews 6/27/2025
Passed: Building - Wall Sheathing Troy Crews 6/27/2025
Passed: Electrical - 2nd Rough-In Troy Crews 6/27/2025
Passed: Mechanical - Rough In Troy Crews 6/27/2025
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 6/27/2025
Passed: Building - Insulation Troy Crews 7/9/2025
Failed: Electrical - Permanent Power Need Confirmation Of Ufer Ground Connection Seems To Be Behind This Siding May Need To Drive A Ground Rod Troy Crews 8/4/2025
Passed: Electrical - Permanent Power Ground Rod Installed Troy Crews 8/5/2025
Release to power company Ok To Release Power-- City Tap Inspection Required Prior To Final, Blower Door, & Termite Final Required Prior To Co-- 8.6.25 Mg Troy Crews 8/5/2025
Submitted Power Release through FPL Portal Garber, Melissa 8/6/2025
Passed: City of Lake City Utilities - Lake City Utilities Tap Inspection City Of Lake City Distribution And Collections Department 9/4/2025
Passed: Building - Final Borate For Termite. All Requirements Met To Release Co-- 9.4.25 Mg Troy Crews 9/4/2025

Documents

File Name Date File Size
Termite Treatment - Final 50921.jpg 2025.09.16 52.79kB
Blower Door Test Results 20250909 083253.pdf 2025.09.16 106.33kB
Certificate Of Occupancy 20250912.pdf 2025.09.12 101.22kB
Application Information Page 20241015 082650 (1).pdf 2025.07.05 389.16kB
Elevation Letter 460 Sw Marynik Drive, High Springs, Fl 10-17-24.pdf 2025.07.04 791.19kB
66712 Lidar 2024-08-21 12.25.39.954.pdf 2025.06.22 122.70kB
911 Address Form 20241015 082649.pdf 2025.06.22 155.30kB
Roof Inspection Affidavit By Contractor 20241015 082751.pdf 2025.06.22 187.62kB
Application Information Page 20241015 082449.pdf 2025.06.22 202.49kB
Product Approval Code Specifications Form 20241015 082748.pdf 2025.06.22 220.59kB
Property Appraiser Parcel Details Printed Page 20241015 082648.pdf 2025.06.22 239.48kB
Srwmd Enhanced Snapshot 16-7s-17-10006-213 2024-08-21 12.25.40.220.pdf 2025.06.22 300.23kB
Application Information Page 20241015 082650.pdf 2025.06.22 389.16kB
Septic Approval Paperwork 20241015 082550.pdf 2025.06.21 585.63kB
Subcontractor Form 20241015 082549.pdf 2025.06.21 748.36kB
Residential Or Commercial Checklist 20241015 082749.pdf 2025.06.21 1.59MB
Metal Building Plans 20241015 082847.pdf 2025.06.21 1.42MB
Energy Code Forms 20241015 083248.pdf 2025.06.20 4.32MB
Big Plans 005.pdf 2025.06.19 694.19kB
Big Plans 006.pdf 2025.06.19 709.24kB
Big Plans 002.pdf 2025.06.19 845.97kB
Truss Engineering 20241015 083148.pdf 2025.06.19 7.22MB
Big Plans 003.pdf 2025.06.19 877.71kB
Big Plans 001.pdf 2025.06.19 939.88kB
Big Plans 004.pdf 2025.06.19 994.83kB
Power Release-release To Power Company 20250527.pdf 2025.05.27 39.31kB
Power Release-electrical-permanent Power 20250501.pdf 2025.05.01 39.31kB
Power Release-electrical-temporary Service 20241031.pdf 2024.10.31 39.20kB
Recorded Noc.pdf 2024.10.30 180.74kB
Updated Permit 20241030.pdf 2024.10.30 46.46kB
Original Permit 20241001.pdf 2024.10.01 46.44kB

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.