Permit Details

Permit Search

Permit

Roof Replacement or Repair

3726 SW COUNTY ROAD 242
LAKE CITY, FL 32024

Permit #
000053075
Application #
70858
Status Completed
  1. Submitted May 2, 2025
  2. Issued May 12, 2025
  3. Expires Dec 10, 2025
  4. Completed Jun 13, 2025

Property

Parcel #
03220-010
Owner
Hartzog Jerry R, Hartzog Gail C
Acres
5.02
Subdivision
—
Zoning
RR
Flood zone
X
District
2

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0380C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Tear off existing shingles and replace with new GAF Timberline shingles
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
4000
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL-10124-R31
Product Manufacturer
GAF
Product Description
Architectural shingle
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Documents Required
  4. Final Review - Documents Required
  5. Final Review - Payment Needed
  6. Final Review - Reviewed
  7. Permit Issued
  8. Final Review - Complete

Contractors

  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CCC1329482
    Title
    Roofing Contractor
    Role
    Contractor

Inspections

  1. Jun 9, 2025

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  2. Jun 13, 2025

    Passed: Re-Roof - Final

    Re Shingle

    Inspected by Matt Forsyth