Permit Details

Permit Search

Permit

New Residential Construction

589 SW KICKLIGHTER TER
LAKE CITY, FL 32024

Permit #
000053074
Application #
69996
Status Completed
  1. Submitted Mar 19, 2025
  2. Issued May 12, 2025
  3. Expires May 20, 2026
  4. Completed Dec 3, 2025

Property

Parcel #
03108-002
Owner
Almonte Elvia Guadalupe, Norman Jared Michael
Acres
2.09
Subdivision
—
Zoning
RR
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0293D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2137
Total Area (Sqft)
2977
Building Height
22.8
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0198
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
50

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Point Review - Printed-Online Application
  5. Point Review - Reviewed
  6. Zoning Review - Reviewed
  7. Plan Review - Corrections Needed
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Plan Review - Documents Required
  11. Plan Review - Documents Required
  12. Plan Review - Building Approved
  13. Plan Review - Electrical Approved
  14. Plan Review - Mechanical Approved
  15. Plan Review - Plumbing Approved
  16. Plan Review - Fuel/Gas Approved
  17. Plan Review - Reviewed
  18. Final Review - Corrections Needed
  19. Final Review - Processing
  20. Final Review - Reviewed
  21. Final Review - Reviewed
  22. Final Review - Complete
  23. Permit Issued

Contractors

  • Tyler Stratton

    Stratton Plumbing

    License
    CFC1432618
    Title
    Cert. Plumbing
    Role
    Subcontractor
  • Richard J Turner

    Turner Electrical Services

    License
    ES12000280
    Title
    Specialty Residential Electric
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Matthew Green

    Greens Sales & Services 2 Inc

    License
    CAC1820394
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor
  • Patrick Jones

    Chrismill Homes Of Florida Inc

    License
    CRC1332817
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License Expired.

  • Angel Baez

    Kings Roofing Nwfl Llc

    License
    CCC1333188
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Mar 20, 2025

    Septic Release Inspection

    Inspected by Health Dept

  2. Jun 10, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Gary Pitzer

  3. Jun 10, 2025

    Passed: Electrical - 1st Underground Rough–In

    Under Slab Electric Conduit

    Inspected by Gary Pitzer

  4. Jun 12, 2025

    Cancelled: Building - Footer

    Inspected by Gary Pitzer

  5. Jun 12, 2025

    Cancelled: Engineering - Setbacks

    Inspected by Gary Pitzer

  6. Jun 13, 2025

    Passed: Engineering - Setbacks

    Appears To Be With-in Limits

    Inspected by Gary Pitzer

  7. Jun 13, 2025

    Failed: Building - Footer

    1. No Electrical Footer Bond 2. Wrong Type Tape On Plastic, Need Portalet At Site, Termite Underslab Treatment Paper , Photos Will Satisfy These Defects Send Via Text To 386-292-0220. Questions Call

    Inspected by Gary Pitzer

  8. Jun 17, 2025

    Passed: Engineering - Setbacks

    Inspected by Gary Pitzer

  9. Jun 17, 2025

    Passed: Building - Footer

    Inspected by Gary Pitzer

  10. Jul 21, 2025

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  11. Jul 21, 2025

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  12. Aug 28, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Aug 28, 2025

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Aug 28, 2025

    Passed: Mechanical - Above Ceiling

    Inspected by Matt Forsyth

  15. Aug 28, 2025

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  16. Aug 29, 2025

    Passed: Building - Framing

    Inspected by Matt Forsyth

  17. Sep 5, 2025

    Passed: Building - Insulation

    Inspected by Troy Crews

  18. Nov 7, 2025

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  19. Nov 7, 2025

    Release to power company

    Inspected by Troy Crews

  20. Nov 21, 2025

    Passed: Building - Final

    All Requirements Met To Release Co-- 12.3.25 Mg

    Inspected by Matt Forsyth

Documents