Permit Details

Permit Search

Permit

New Residential Construction

305 SW CADENCE GLN
LAKE CITY, FL 32024

Permit #
000052841
Application #
70224
Status Completed
  1. Submitted Apr 2, 2025
  2. Issued Apr 7, 2025
  3. Expires Jan 25, 2026
  4. Completed Jul 29, 2025

Property

Parcel #
03001-107
Owner
Maronda Homes Llc,
Acres
0.99
Subdivision
Forest Cove
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
1' above the crown of the road
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0289D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2052
Total Area (Sqft)
2475
Building Height
21
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0278
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Reviewed
  4. Zoning Review - Reviewed
  5. Plan Review - Plumbing Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Building Approved
  9. Plan Review - Reviewed
  10. Final Review - Processing
  11. Final Review - Corrections Needed
  12. Final Review - Payment Needed
  13. Permit Issued
  14. Final Review - Payment Needed
  15. Final Review - Complete

Contractors

  • Adam Gaslin

    Maronda Homes Llc Of Florida

    License
    CRC1331630
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Paul K Coleman

    Colemans Plumbing Inc.

    License
    CFC1425624
    Title
    Certified Plumbing
    Role
    Subcontractor

    County License & State License & Employees Workers Comp Expired.

  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor
  • Ryan Hinote

    Nature Coast Electrical

    License
    EC13011934
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Robert M Bounds

    Bounds Heating & Air Inc

    License
    CAC057642
    Title
    Class A A/c
    Role
    Subcontractor

Inspections

  1. Apr 25, 2025

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  2. Apr 25, 2025

    Release to power company

    Inspected by Matt Forsyth

  3. May 1, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Water Supply Under Slab

    Inspected by Matt Forsyth

  4. May 6, 2025

    Passed: Building - Monolithic Slab

    Inspected by Matt Forsyth

  5. May 6, 2025

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  6. May 15, 2025

    Passed: Building - Masonry Wall Reinforcing

    Clean Outs Inspected

    Inspected by Matt Forsyth

  7. May 21, 2025

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  8. May 21, 2025

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. May 28, 2025

    Passed: Building - Framing

    Concrete Lentil Ties For Roof Framing

    Inspected by Matt Forsyth

  10. Jun 5, 2025

    Passed: Electrical - 1st Underground Rough–In

    2nd Rough

    Inspected by Matt Forsyth

  11. Jun 5, 2025

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  12. Jun 6, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Jun 6, 2025

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Matt Forsyth

  14. Jun 9, 2025

    Passed: Building - Insulation

    Walls And Garage To Habitable Dwelling

    Inspected by Matt Forsyth

  15. Jun 20, 2025

    Septic Release Inspection

    Inspected by Health Dept

  16. Jul 8, 2025

    Cancelled: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  17. Jul 10, 2025

    Passed: Electrical - Permanent Power

    Drive Rec'd

    Inspected by Matt Forsyth

  18. Jul 16, 2025

    Release to power company

    Inspected by Mgarber

  19. Jul 25, 2025

    Failed: Building - Final

    Need To Complete Repairs Around Exterior Outlet Boxes Double Vanity Bathroom Needs An Additional Outlet Or The Outlet Needs To Be Centered

    Inspected by Troy Crews

  20. Jul 29, 2025

    Passed: Building - Final

    All Requirements Met To Release Co-- 7.29.25 Mg

    Inspected by Matt Forsyth

Documents