Permit Details

Permit Search

Permit

Mobile Home

320 SW HICKORY GLN
FORT WHITE, FL 32038

Permit #
000052799
Application #
70001
Status Completed
  1. Submitted Mar 19, 2025
  2. Issued Apr 2, 2025
  3. Expires Dec 9, 2025
  4. Completed Jun 12, 2025

Property

Parcel #
00488-090
Owner
Cherepenina Elena,
Acres
1.07
Subdivision
Spring Hills
Zoning
ESA-2
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
Bottom of lowest beam must be one foot above the road
Fema map number
12023C0370C
Mobile Home is a:
Double Wide
Year Built
2025
Width (Ft.In)
28
Length (Ft.In)
60
Driveway access to home:
Ft White
Installation Decal #
119255
Septic #
25-0272
Setbacks Front
30'
Setback Side 1
25'
Setbacks Rear
25'
Dev Permit #
F023-
Setback Side 2
25'
Are you applying for a 5 year temporary permit?
No
Serial #
LOHGA20040531AB
Wind Zone?
2
Residential or Commercial Use?
Residential
Service Amps
200
How many of bedrooms does this home have?
4
How many bathrooms does this home have?
2

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Processing
  4. Point Review - Printed-Online Application
  5. Point Review - On Hold-Incomplete
  6. Point Review - Printed-Online Application
  7. Point Review - Reviewed
  8. Zoning Review - Reviewed
  9. Plan Review - Reviewed
  10. Final Review - Payment Needed
  11. Permit Issued

Contractors

  • Wendell Crews

    License
    IH1025316
    Title
    Mh Installer (ih)
    Role
    Contractor

    County License & State License Expired.

  • Michael Boland

    Ace A/c Of Ocala Llc

    License
    ES12000926
    Title
    Cert. Electrical Specialty
    Role
    Subcontractor
  • Michael A Boland

    Ace A/c Of Ocala Llc

    License
    CAC1817716
    Title
    Cert Class B A/c
    Role
    Subcontractor

Inspections

  1. May 16, 2025

    Failed: Mobile Home - Mobile Home Set-Up Final

    Need Dirt Base In Front Of Metercan To Safely Open

    Inspected by Matt Forsyth

  2. May 16, 2025

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. May 23, 2025

    Passed: Engineering - Setbacks

    Inspected by Gary Pitzer

  4. May 23, 2025

    Passed: Mobile Home - Mobile Home Set-Up Final

    Need Final Septic Release And Final Drive Prior To Release Of Power And Co-- 5.23.25 Mg, Email Sent-- 6.3.25 Mg-- Rec'd 6.12.25 Mg

    Inspected by Gary Pitzer

  5. Jun 10, 2025

    Septic Release Inspection

    Inspected by Health Dept

  6. Jun 12, 2025

    Release to power company

    Inspected by Melissa Garber

  7. Jun 12, 2025

    Passed: Certificate-Release Certificate

    Inspected by Melissa Garber

  8. Requested

    Building - Vertical Cells/Columns

    Awaiting inspection