Permit Details

Permit Search

Permit

New Commercial Construction

149 SW WOOLSEY GLN
LAKE CITY, FL 32024

Permit #
000052789
Application #
68470
Status Completed
  1. Submitted Dec 5, 2024
  2. Issued Apr 2, 2025
  3. Expires Apr 8, 2026
  4. Completed Oct 10, 2025

Property

Parcel #
02719-000
Owner
Woods Project Llc,
Acres
7.12
Subdivision
—
Zoning
CI
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0291D
This is the construction of a:
Game Room/Metal Building
Driveway access to property:
D.O.T. Permit
Is there a Fire Sprinkler System?
No
Setbacks Front
20'
Setback Side 1
0'
Setback Side 2
0'
Setback Rear
15'
Describe commercial use:
Entertainment
Stories
1
Heated Area (Sqft)
1600
Total Area (Sqft)
1600
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Assembly
Dev Permit #
F023-
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0827
Sealed roof decking options. (Must select one.)
Other (explain)
Service Amps
440

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Point Review - Processing
  5. Zoning Review - Documents Required
  6. Zoning Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Plan Review - Documents Required
  11. Plan Review - Documents Required
  12. Plan Review - Documents Required
  13. Plan Review - Documents Required
  14. Plan Review - Documents Required
  15. Plan Review - Documents Required
  16. Plan Review - Documents Required
  17. Zoning Review - Reviewed
  18. Plan Review - Building Approved
  19. Plan Review - Reviewed
  20. Final Review - Processing
  21. Final Review - Payment Needed
  22. Permit Issued

Contractors

  • Josh Sparks

    Sparks Construction

    License
    CBC1252260
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Ralph W Laverdure

    Rwl Roofing Llc

    License
    CCC1328590
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Benjamin L Sparks

    Line Electric Company Llc

    License
    EC13009101
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License Expired.

  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor

Inspections

  1. Mar 10, 2025

    Passed: Fire - Plan Review

    Inspected by Cpt. Shane Overstreet

  2. May 7, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    S.w.area

    Inspected by Troy Crews

  3. May 22, 2025

    Failed: Building - Slab

    Multiple Cave In Spots, Steel Has No Overlap In Corners Of Strip Footers, Matts Need Better Separation From Each Other

    Inspected by Troy Crews

  4. May 22, 2025

    Passed: Building - Monolithic Slab

    Items Corrected

    Inspected by Troy Crews

  5. May 22, 2025

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  6. Jun 26, 2025

    Passed: Electrical - 1st Underground Rough–In

    Ground Rods At Main Distribution And Underground Conduit

    Inspected by Troy Crews

  7. Jun 30, 2025

    Failed: Electrical - Service Upgrade Final

    No Perm Power Until Building Enclosed With Lockable Doors And Septic Final

    Inspected by Troy Crews

  8. Jul 10, 2025

    Passed: Electrical - Temporary Service

    Main Service To Be Used As Temporary Power Due To Power Company Configuration No Sub Panels Are Approved Until Each Have An Inspection

    Inspected by Troy Crews

  9. Jul 10, 2025

    Release to power company

    Inspected by Troy Crews

  10. Oct 3, 2025

    Passed: Fire - Fire Final

    Ok Per Shane Overstreet 10-3-25

    Inspected by Troy Crews

  11. Oct 3, 2025

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  12. Oct 3, 2025

    Release to power company

    Inspected by Troy Crews

  13. Oct 3, 2025

    Passed: Building - Final

    Final Inspection Complete. Permit Under Office Review For Co Eligibility.

    Inspected by Troy Crews

  14. Oct 10, 2025

    Release to power company

    Rec'd Septic Final

    Inspected by Ewilliams

  15. Oct 10, 2025

    Passed: Certificate-Release Certificate

    Rec'd Septic

    Inspected by Crews, Malcolm T.

  16. Oct 10, 2025

    Septic Release Inspection

    Inspected by Health Dept

Documents