Permit Details

Permit Search

Permit

New Residential Construction

563 SW CATHERINE LN
LAKE CITY, FL 32025

Permit #
000052250
Application #
66562
Status Completed
  1. Submitted Dec 9, 2024
  2. Issued Feb 4, 2025
  3. Expires Oct 18, 2026
  4. Completed Apr 29, 2026

Property

Parcel #
09325-002
Owner
Judd James R, Judd Sherry B
Acres
11.08
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0415C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2400
Total Area (Sqft)
2880
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
25-0026
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
Other (explain)
Sealed roof decking explanation for other option.
prefab metal building
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Processing
  4. Point Review - On Hold-Incomplete
  5. Zoning Review - Reviewed
  6. Point Review - Printed-Online Application
  7. Point Review - Reviewed
  8. Plan Review - Corrections Needed
  9. Plan Review - Corrections Needed
  10. Plan Review - Corrections Needed
  11. Plan Review - Building Approved
  12. Plan Review - Electrical Approved
  13. Plan Review - Mechanical Approved
  14. Plan Review - Plumbing Approved
  15. Plan Review - Fuel/Gas Approved
  16. Plan Review - Reviewed
  17. Final Review - Documents Required
  18. Final Review - Documents Required
  19. Zoning Review - Reviewed
  20. Final Review - Documents Required
  21. Final Review - Payment Needed
  22. Permit Issued
  23. Point Review - Reviewed

Contractors

This is an owner-builder project.

Inspections

  1. Feb 17, 2025

    Rescheduled 2/17/2025:Plumbing/Gas - 1st Underground Rough–In

    Inspected by Melissa Garber

  2. Feb 17, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  3. Feb 20, 2025

    Cancelled: Building - Monolithic Slab

    Inspected by Gary Pitzer

  4. Feb 20, 2025

    Cancelled: Engineering - Setbacks

    Inspected by Gary Pitzer

  5. Feb 20, 2025

    Cancelled: Electrical - 1st Underground Rough–In

    Inspected by Gary Pitzer

  6. Feb 21, 2025

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Anthony Aslan

  7. Feb 21, 2025

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  8. Feb 21, 2025

    Passed: Engineering - Setbacks

    Appears With In Setbacks

    Inspected by Anthony Aslan

  9. Feb 21, 2025

    Cancelled: Building - Slab

    Inspected by Anthony Aslan

  10. May 6, 2025

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  11. May 19, 2025

    Release to power company

    Temp Power

    Inspected by Anthony Aslan

  12. Jun 6, 2025

    Passed: Building - Roof Decking

    Metal Building

    Inspected by Anthony Aslan

  13. Jun 6, 2025

    Passed: Building - Wall Sheathing

    Metal Building

    Inspected by Anthony Aslan

  14. Jun 11, 2025

    Septic Release Inspection

    Inspected by Health Dept

  15. Nov 13, 2025

    Passed: Building - Spot Check

    Work In Progress To Finals

    Inspected by Gary Pitzer

  16. Jan 29, 2026

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  17. Jan 29, 2026

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  18. Jan 29, 2026

    Passed: Building - Framing

    Inspected by Troy Crews

  19. Jan 29, 2026

    Passed: Building - Insulation

    Inspected by Troy Crews

  20. Jan 29, 2026

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  21. Apr 6, 2026

    Passed: Electrical - Permanent Power

    Inspected by Gary Pitzer

  22. Apr 6, 2026

    Release to power company

    Inspected by Gary Pitzer

  23. Apr 21, 2026

    Passed: Building - Final

    *all Requirements Met To Release Co-- 4.24.26 Mg

    Inspected by Gary Pitzer

Documents