Permit Details

Permit Search

Permit

Roof Replacement or Repair

292 SW POWELL GLN
FORT WHITE, FL 32038

Permit #
000051991
Application #
68799
Status Completed
  1. Submitted Dec 31, 2024
  2. Issued Jan 6, 2025
  3. Expires Aug 2, 2025
  4. Completed Feb 3, 2025

Property

Parcel #
03737-114
Owner
Caines Aaron A, Caines Devin N
Acres
10.03
Subdivision
Turkey Haven Unr
Zoning
ESA-2
Flood zone
X
District
2

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0390C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
RES REROOF, 6/12, 53SQ, SHINGLE, 2-PLY SYNTHETIC UNDERLAYMENT
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
53
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Explain if not removing the existing roofing material?
REMOVE SHINGLES AND REPLACE WITH NEW SHINGLES
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
10674.1
Other Roofing Product Type Not Listed
15216.1 , 10758.3
Product Manufacturer
OWENS CORNING
Product Description
SYNTHETIC UNDERLAYMENT AND COBRA RIDGE VENT
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Sealed roof decking explanation for other option.
USING SHINGLES, 2-PLY SYNTHETIC UNDERLAYMENT AND SKYRUNNER RIDGE VENT
Ventilation:
Ridge Vent
Flashing:
Repair Existing
Drip Edge:
Replace All
Valley Treatment:
Use Existing
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Corrections Needed
  4. Final Review - Payment Needed
  5. Permit Issued

Contractors

  • Shane Schillings

    Quality First Roofing, Llc

    License
    CCC1331249
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License Expired.

Inspections

  1. Jan 14, 2025

    Passed: Re-Roof - In Progress

    In Progress With Finishing Roof At Time Of Inspection. In The Future Please Have Use At The Site At The Time Of Tear Off. We Need To Do A In Progress Inspection. Project Was Nearly Complete, Power Vent And Ridge Vent. Please Post Good Photos On Our Site Per Your Affidavit

    Inspected by Gary Pitzer

  2. Feb 3, 2025

    Passed: Re-Roof - Final

    Shingle Roof Covering

    Inspected by Gary Pitzer