Permit Details

Permit Search

Permit

New Residential Construction

220 SW BEDENBAUGH LN
LAKE CITY, FL 32025

Permit #
000051308
Application #
67413
Status Completed
  1. Submitted Oct 8, 2024
  2. Issued Oct 29, 2024
  3. Expires Oct 14, 2025
  4. Completed Apr 22, 2025

Property

Parcel #
08944-032
Owner
Parsons Stephen M, Parsons Mary D
Acres
3.15
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0401C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2169
Total Area (Sqft)
3533
Building Height
23
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0771
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Fuel/Gas Approved
  9. Plan Review - Reviewed
  10. Zoning Review - Status Cleared
  11. Zoning Review - Reviewed
  12. Final Review - Processing
  13. Final Review - Processing
  14. Final Review - Payment Needed
  15. Permit Issued

Contractors

  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CGC1516042
    Title
    General Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CCC1329482
    Title
    Roofing Contractor
    Role
    Subcontractor
  • Ryan Felknor

    Felknor Electric, Inc.

    License
    EC13003153
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor

Inspections

  1. Oct 31, 2024

    Passed: Building - Footer

    Inspected by Anthony Aslan

  2. Oct 31, 2024

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  3. Nov 19, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  4. Dec 4, 2024

    Rescheduled 12/4/2024:Building - Slab

    Inspected by Troy Crews

  5. Dec 4, 2024

    Passed: Building - Slab

    #5 Perimeter Bar Porches Recommended

    Inspected by Matt Forsyth

  6. Dec 12, 2024

    Passed: Electrical - Temporary Service

    Existing Power Pole With Gfci Below

    Inspected by Gary Pitzer

  7. Dec 12, 2024

    Release to power company

    Inspected by Gary Pitzer

  8. Dec 31, 2024

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  9. Jan 7, 2025

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  10. Jan 21, 2025

    Passed: Building - Framing

    Inspected by Matt Forsyth

  11. Jan 21, 2025

    Passed: Electrical - 2nd Rough-In

    Pigtails Hanging Out Of Boxes

    Inspected by Matt Forsyth

  12. Jan 21, 2025

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  13. Jan 21, 2025

    Passed: Plumbing/Gas - 2nd Rough-In

    Tub Water Tested

    Inspected by Matt Forsyth

  14. Jan 27, 2025

    Passed: Building - Insulation

    Spray Foam Insulation

    Inspected by Matt Forsyth

  15. Mar 24, 2025

    Rescheduled 3/24/2025:Electrical - Permanent Power

    Inspected by Troy Crews

  16. Mar 24, 2025

    Passed: Electrical - Permanent Power

    Septic

    Inspected by Matt Forsyth

  17. Mar 28, 2025

    Release to power company

    Inspected by Melissa Garber

  18. Mar 28, 2025

    Septic Release Inspection

    Inspected by Health Dept

  19. Apr 17, 2025

    Passed: Building - Final

    Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents.

    Inspected by Matt Forsyth

  20. Apr 22, 2025

    Certificate-Release Certificate

    Inspected by Matt Forsyth

Documents