Permit Details

Permit Search

Permit

New Residential Construction

183 SW SILVER PALM DR
LAKE CITY, FL 32024

Permit #
000051048
Application #
66651
Status Completed
  1. Submitted Aug 15, 2024
  2. Issued Dec 5, 2024
  3. Expires Sep 24, 2025
  4. Completed Mar 28, 2025

Property

Parcel #
02731-141
Owner
Adams Homes Of Nw Fl, Inc.
Acres
0.25
Subdivision
Preserve At Laurel Lake Unit 1
Zoning
PRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
117.6'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0290D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2265
Total Area (Sqft)
3094
Building Height
15
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. City of Lake City Utilities Notified.
  3. Application submitted by applicant.
  4. City of Lake City Utilities Notified.
  5. Point Review - Printed-Online Application
  6. Point Review - Reviewed
  7. Zoning Review - Reviewed
  8. Plan Review - Plumbing Approved
  9. Plan Review - Mechanical Approved
  10. Plan Review - Electrical Approved
  11. Plan Review - Building Approved
  12. Plan Review - Reviewed
  13. Final Review - Documents Required
  14. Final Review - Processing
  15. Final Review - Reviewed
  16. Final Review - Payment Needed
  17. Permit Issued
  18. Permit Reissued
  19. Permit Reissued

Contractors

  • William Adams

    Adams Homes Of Northwest Florida Inc

    License
    CRC1330146
    Title
    Cert. Residential
    Role
    Contractor
  • Shawn Reynolds

    Ncf Electrical Services Llc

    License
    EC13011927
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Derrick L Williams

    D L Williams Heating & Cooling Llc

    License
    CAC1816913
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Benjamin T Keeler

    Keeler Roofing, Llc

    License
    CCC1330509
    Title
    Cert. Roofing
    Role
    Subcontractor

Inspections

  1. Nov 15, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  2. Nov 18, 2024

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  3. Nov 18, 2024

    Passed: Engineering - Setbacks

    To Be Checked By Surveyor

    Inspected by Troy Crews

  4. Dec 6, 2024

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  5. Dec 6, 2024

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  6. Dec 12, 2024

    Passed: Building - Framing

    Inspected by Troy Crews

  7. Dec 12, 2024

    Passed: Building - Strapping

    Inspected by Troy Crews

  8. Dec 12, 2024

    Failed: Plumbing/Gas - Tub Set/Shower Pan

    No Pressure On Water Lines Call It Back In With Insulation

    Inspected by Troy Crews

  9. Dec 12, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  10. Dec 12, 2024

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  11. Dec 12, 2024

    Failed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  12. Dec 23, 2024

    Failed: Building - Insulation

    Not Done

    Inspected by Troy Crews

  13. Dec 23, 2024

    Failed: Plumbing/Gas - 2nd Rough-In

    No Pressure On Water Lines

    Inspected by Troy Crews

  14. Dec 23, 2024

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Troy Crews

  15. Dec 27, 2024

    Passed: Building - Insulation

    Inspected by Troy Crews

  16. Jan 30, 2025

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  17. Jan 30, 2025

    Release to power company

    Inspected by Troy Crews

  18. Mar 27, 2025

    Passed: City of Lake City Utilities - Lake City Utilities Tap Inspection

    Inspected by City Of Lake City Distribution And Collections Department

  19. Mar 28, 2025

    Passed: Building - Final

    Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents.

    Inspected by Troy Crews

Documents