Permit Details

Permit Search

Permit

Roof Replacement or Repair

350 SW NAUTILUS RD
LAKE CITY, FL 32024

Permit #
000051026
Application #
67415
Status Completed
  1. Submitted Oct 8, 2024
  2. Issued Oct 11, 2024
  3. Expires May 11, 2025
  4. Completed Nov 12, 2024

Property

Parcel #
09283-000
Owner
Feagle David W Fam Trust & Feagle Ellen S Fam Trust
Acres
89.87
Subdivision
—
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0395C
Type Roofing Job
Overlay with Metal
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
4600
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
No
Explain if not removing the existing roofing material?
Metal over existing shingles
Type of New Roofing Product
Metal
Florida Product Approval Number
17992.IR2
Product Manufacturer
Capital Metal
Product Description
29 Gauge Metal
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
Other (explain)
Sealed roof decking explanation for other option.
pine centers over existing shingles
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Kevin L Bedenbaugh Jr

    Plumb Level Construction Co Llc

    License
    CCC1329482
    Title
    Roofing Contractor
    Role
    Contractor

Inspections

  1. Oct 22, 2024

    Passed: Re-Roof - In Progress

    Roof In Progress,

    Inspected by Gary Pitzer

  2. Nov 4, 2024

    Failed: Re-Roof - Final

    1.need More Photo To Support Affidavit, 2 Several Places Starter Trim Does Not Meet Fascia, 3. Fascia Missing In One Place And Another Fascia Is Not Behind Roof Trim, 4. One Ridge Has Opening That Needs Closed, 5. Owner Unhappy With Job And Wants To Wait Till After Heavy Rain To Close Permit

    Inspected by Gary Pitzer

  3. Nov 12, 2024

    Passed: Re-Roof - Final

    Owner Not On Site. Contractor Stated That He Explain The Roof Details With Him

    Inspected by Gary Pitzer