Permit Details

Permit Search

Permit

Roof Replacement or Repair

190 SE CUSTER WAY
LAKE CITY, FL 32025

Permit #
000050756
Application #
66834
Status Completed
  1. Submitted Sep 3, 2024
  2. Issued Sep 6, 2024
  3. Expires Mar 12, 2025
  4. Completed Sep 13, 2024

Property

Parcel #
08300-084
Owner
Williams Robert A, Williams Meyna M
Acres
0.41
Subdivision
Woodhaven Unit Iv
Zoning
RSF-2
Flood zone
AH
District
5

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0313D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Replace wood as needed
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
38
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL18355-R8
Product Manufacturer
TAMKO
Product Description
HERITAGE
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Final Review - Documents Required
  5. Final Review - Payment Needed
  6. Permit Issued

Contractors

  • Lewis G Walker

    Lewis Walker Roofing Inc

    License
    CCC1333551
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Sep 9, 2024

    Passed: Re-Roof - In Progress

    Inspected by Gary Pitzer

  2. Sep 13, 2024

    Passed: Re-Roof - Final

    Inspected by Anthony Aslan