Permit Details

Permit Search

Permit

Roof Replacement or Repair

6037 W US HIGHWAY 90
LAKE CITY, FL 32055

Permit #
000050359
Application #
65719
Status Completed
  1. Submitted Jun 6, 2024
  2. Issued Jul 16, 2024
  3. Expires Mar 4, 2025
  4. Completed Sep 5, 2024

Property

Parcel #
02382-006
Owner
North Central Florida Hospice Inc
Acres
6.79
Subdivision
—
Zoning
CI
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0280D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Remove single layer of shingles /felt to expose decking for examination, re-nail decking to meet current code as needed, Provide/Install new 8" off ridge vents to replace existing, Reuse/reseal existing metal flashing details when possible, Provide/Install new factory painted galvanized eaves drip, Provide/Install OC WeatherLock on areas where pitch is below 4in12, P/I 2 layers of OC ProArmor synthetic underlayment, P/I OC WeatherLock Mat self-adhered leak barriers in valleys, P/I OC Starter Roll at eaves,P/I OC OakRidge Architectural shingles, P/I Oentsure Heat & Moisture Ridge Vent, P/I OC ProEdge hip and ridge cap, P/I new bullet boot pipe flashings and exhaust vent flashings
Type of structure
Commercial Building
Commercial or Residential
Commercial
Roof Area (for this job) Sq Ft
23059
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10674.1
Other Roofing Product Type Not Listed
OC ProArmor Synthetic Underlayment Product Approval code 14299.1
Product Manufacturer
Owens Corning
Product Description
OC OakRidge Architectural
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Final Review - Corrections Needed
  5. Final Review - Corrections Needed
  6. Final Review - Corrections Needed
  7. Final Review - Corrections Needed
  8. Final Review - Payment Needed
  9. Permit Issued

Contractors

  • Warren K Perry

    Perry Roofing Contractors

    License
    CCC042888
    Title
    Roofing Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Aug 5, 2024

    Passed: Re-Roof - In Progress

    Inspected by Troy Crews

  2. Aug 29, 2024

    Rescheduled 9/3/2024:Re-Roof - Final

    Inspected by Troy Crews

  3. Sep 3, 2024

    Failed: Re-Roof - Final

    Only One Picture In File

    Inspected by Troy Crews

  4. Sep 5, 2024

    Passed: Re-Roof - Final

    For Future Need More Pictures Of Plywood Nailing And Underlayment.

    Inspected by Troy Crews