Permit Information

New Residential Construction Permit

Address 701 SE TIMBERLINE RANCH GLEN
LAKE CITY, FL 32025
Parcel #: 09218-004
Acres:11.99
Owner:Shaw Angelica C, Shaw William Seth
Subdivision:
Zoning:A-3
Flood Zone:X
District:4
Application #:65438
Permit #: 000050286
Related Permit:
Submitted:Monday, May 20, 2024
Issued:Wednesday, July 3, 2024
Expires:Monday, January 6, 2025
Completed:Monday, January 6, 2025
Status: Completed
Septic Release? Yes

Notes

*MFE= 1' ABOVE THE ROAD

Job Details

Finished floor requirement
Fema map number 12023C0280D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Crown Tile, Batten system, TU Max underlayment
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 0.00
No. of Stories 2
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Concrete
Florida Product Approval Number FL16729-R5
Product Manufacturer Crown
Product Description Tile
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Sealed roof decking explanation for other option. TU Max underlayment
Ventilation: Off-ridge Vent
Flashing: Repair Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Second Roof Pitch (if applicable) 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No

Review Notes

5/20/2024 Application pending.
5/20/2024 Application submitted by applicant.
5/21/2024 Point Review - On Hold-Incomplete
6/11/2024 Point Review - Printed-Online Application
6/24/2024 Zoning Review - Reviewed
6/26/2024 Plan Review - Plumbing Approved
6/26/2024 Plan Review - Mechanical Approved
6/26/2024 Plan Review - Electrical Approved
6/26/2024 Plan Review - Building Approved
6/26/2024 Plan Review - Reviewed
6/26/2024 Final Review - Documents Required
7/2/2024 Final Review - Reviewed
7/2/2024 Final Review - Payment Needed
7/3/2024 Permit Issued

Contractors

Name / Business License Title Role
Roger Whiddon
Lake City Plumbing Inc
County License & State License Expired.
CFC1428686 Cert Plumbing Subcontractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Robert Jarvis
Jarvis Heat And Air Llc
County License & State License Expired.
CAC1816766 Class "b" A/c Subcontractor
William B Scott
William Scott Construction,inc.
County License & State License Expired.
CBC1250835 Building Contractor Contractor
Roger Whiddon
Lake City Plumbing Inc
County License & State License Expired.
CFC1428686 Cert Plumbing Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Dvw And Water Under Slab, Exterior Clean Out Installed Need Compaction Test For Slab Gary Pitzer 7/24/2024
Cancelled: Building - Footer Anthony Aslan 7/31/2024
Cancelled: Engineering - Setbacks Anthony Aslan 7/31/2024
Passed: Electrical - 1st Underground Rough–In Anthony Aslan 7/31/2024
Passed: Engineering - Setbacks Appears Within Setbacks Anthony Aslan 7/31/2024
Passed: Building - Monolithic Slab Anthony Aslan 7/31/2024
Passed: Building - Wall Sheathing Anthony Aslan 9/9/2024
Passed: Building - Roof Decking Anthony Aslan 9/9/2024
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 9/9/2024
Failed: Building - Framing Not Ready Anthony Aslan 9/9/2024
Cancelled: Building - Strapping Anthony Aslan 9/9/2024
Passed: Electrical - Temporary Service Anthony Aslan 9/16/2024
Release to power company Anthony Aslan 9/16/2024
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 10/1/2024
Passed: Building - Framing Anthony Aslan 10/1/2024
Passed: Building - Strapping Anthony Aslan 10/1/2024
Cancelled: Electrical - 1st Underground Rough–In Anthony Aslan 10/1/2024
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 10/1/2024
Passed: Mechanical - Rough In 181 On Exhaust Fan Connections Anthony Aslan 10/14/2024
Passed: Building - Insulation Spray Foam Attic, Batt In Walls Anthony Aslan 10/14/2024
Passed: Electrical - 2nd Rough-In Anthony Aslan 10/14/2024
Release to power company For Temp. Anthony Aslan 11/20/2024
Cancelled: Electrical - Permanent Power Anthony Aslan 12/26/2024
Cancelled: Building - Final Anthony Aslan 12/30/2024
Passed: Electrical - Permanent Power Needs Septic Approval, Power On At Time Of Inspection Gary Pitzer 12/30/2024
Release to power company Melissa Garber 1/3/2025
Septic Release Inspection Health Dept 1/3/2025
Certificate-Release Certificate Anthony Aslan 1/6/2025
Passed: Building - Final Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents. Anthony Aslan 1/6/2025

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.