Permit Details

Permit Search

Permit

Roof Replacement or Repair

347 NW BRIDGEWATER TER
LAKE CITY, FL 32055

Permit #
000050259
Application #
65943
Status Completed
  1. Submitted Jun 20, 2024
  2. Issued Jul 1, 2024
  3. Expires Feb 17, 2025
  4. Completed Aug 21, 2024

Property

Parcel #
02275-107
Owner
Burnham Marsha M,
Acres
4.53
Subdivision
Cobblestone Unit 1
Zoning
RSF-2
Flood zone
X
District
1

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0283D
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
61
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL30310-R5
Product Manufacturer
IKO Industries Ltd
Product Description
SHINGLES
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
Use Existing
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Documents Required
  4. Final Review - Payment Needed
  5. Permit Issued

Contractors

  • Tristan J Hall

    J&m Residential Services Florida Division, Llc

    License
    CCC1331951
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License Expired.

Inspections

  1. Jul 17, 2024

    Passed: Re-Roof - In Progress

    In Progess

    Inspected by Gary Pitzer

  2. Aug 8, 2024

    Failed: Re-Roof - Final

    No In Progress Pictures Of Your Project Per Your Affidavit On File

    Inspected by Gary Pitzer

  3. Aug 21, 2024

    Passed: Re-Roof - Final

    Inspected by Gary Pitzer