Permit Details

Permit Search

Permit

New Residential Construction

654 SE BALD EAGLE LOOP
LAKE CITY, FL 32025

Permit #
000050190
Application #
64974
Status Completed
  1. Submitted Apr 19, 2024
  2. Issued Jun 24, 2024
  3. Expires Feb 9, 2026
  4. Completed Aug 13, 2025

Property

Parcel #
09533-215
Owner
Dent Gregory H, Dent Judith A
Acres
22.04
Subdivision
—
Zoning
ESA-2
Flood zone
A
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Existing Building
Finished floor requirement
Meet existing structure
Fema map number
12023C0505C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
787
Total Area (Sqft)
1392
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0252
If Other, explain the use of the structure.
accessory dwelling unit
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Reviewed
  2. Point Review - Documents Required
  3. Zoning Review - Reviewed
  4. Plan Review - Documents Required
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Final Review - Documents Required
  9. Plan Review - Documents Required
  10. Final Review - Documents Required
  11. Final Review - Documents Required
  12. Plan Review - Documents Required
  13. Plan Review - Documents Required
  14. Plan Review - Documents Required
  15. Final Review - Documents Required
  16. Plan Review - Documents Required
  17. Final Review - Documents Required
  18. Plan Review - Plumbing Approved
  19. Plan Review - Mechanical Approved
  20. Plan Review - Electrical Approved
  21. Plan Review - Building Approved
  22. Plan Review - Reviewed
  23. Final Review - Documents Required
  24. Final Review - Reviewed
  25. Final Review - Payment Needed
  26. Permit Issued
  27. Final Review - Corrections Needed
  28. Final Review - Corrections Needed
  29. Final Review - Corrections Needed

Contractors

  • Mathew Carlton

    Carlton Contracting, Inc

    License
    CCC1329887
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Len E Eaves

    Prestige Electric Inc

    License
    EC13004956
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Craig Falstreaux

    Craig Falstreaux Heating And Air Inc

    License
    CAC057150
    Title
    Cert Class B A/c
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Daniel D Weiland

    Kevin Mobley Plumbing Llc

    License
    CFC1430423
    Title
    Cert. Plumbing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jun 28, 2024

    Passed: Building - Framing

    Existing Building

    Inspected by Anthony Aslan

  2. Jun 28, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  3. Jun 28, 2024

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  4. Jun 28, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  5. Jun 28, 2024

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Anthony Aslan

  6. Jun 28, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  7. Jul 12, 2024

    Passed: Building - Insulation

    Spray Foam Walls And Attic

    Inspected by Anthony Aslan

  8. Dec 12, 2024

    Passed: Electrical - Permanent Power

    Inspected by Anthony Aslan

  9. Dec 12, 2024

    Release to power company

    Inspected by Anthony Aslan

  10. Dec 12, 2024

    Passed: Building - Final

    Blower Door And Termite Final Required Prior To Co, Email Sent-- 5.18.25 Mg, Email Sent-- 6.3.25 Mg, 6.17.25 Mg, 7.2.25 Mg, 7.21.25 Mg

    Inspected by Anthony Aslan

  11. Apr 4, 2025

    Septic Release Inspection

    Inspected by Health Dept

  12. Aug 13, 2025

    Passed: Certificate-Release Certificate

    Rec'd Blower Door And Termite

    Inspected by Anthony Aslan