Permit Details

Permit Search

Permit

New Residential Construction

134 SW SEDGEFIELD FARMS GLN
FORT WHITE, FL 32038

Permit #
000050014
Application #
63922
Status Permit Renewed This permit expired on Jun 15, 2026.
  1. Submitted Jan 18, 2024
  2. Issued Nov 3, 2025
  3. Expires Jun 15, 2026
  4. Completed —

Property

Parcel #
03767-319
Owner
Copeland Paul Mark,
Acres
5.04
Subdivision
Sedgefield Phase 3
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Permit Renewed
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
12" ABOVE ADJACENT GROUND FOR ENTIRE PERIMETER
Document receieved
No
Fema map number
12023C0480C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1000
Total Area (Sqft)
4900
Building Height
15
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
residential
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0877
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
Other (explain)
Sealed roof decking explanation for other option.
metal building

Status & Review History

  1. Point Review - Reviewed
  2. Plan Review - Documents Required
  3. Plan Review - Documents Required
  4. Plan Review - Documents Required
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Plan Review - Documents Required
  11. Plan Review - Documents Required
  12. Plan Review - Documents Required
  13. Plan Review - Documents Required
  14. Plan Review - Documents Required
  15. Plan Review - Documents Required
  16. Plan Review - Documents Required
  17. Plan Review - Mechanical Approved
  18. Plan Review - Electrical Approved
  19. Plan Review - Building Approved
  20. Plan Review - Reviewed
  21. Zoning Review - Documents Required
  22. Zoning Review - Documents Required
  23. Zoning Review - Documents Required
  24. Zoning Review - Documents Required
  25. Zoning Review - Reviewed
  26. Final Review - Processing
  27. Final Review - Documents Required
  28. Final Review - Documents Required
  29. Final Review - Documents Required
  30. Final Review - Reviewed
  31. Final Review - Payment Needed
  32. Permit Issued
  33. Permit Renewed

Contractors

This is an owner-builder project.

Inspections

  1. Jun 7, 2024

    Failed: Electrical - Temporary Service

    Grounding Electrode Conductor No Attached To Ground Rods

    Inspected by Gary Pitzer

  2. Jun 11, 2024

    Building-Footer

    16 Post Hole Inspection For Main Section, Lean-to Poles Remain For Inspection In The Furture

    Inspected by Gary Pitzer

  3. Jun 13, 2024

    Passed: Building - Footer

    Lean-to Poles

    Inspected by Anthony Aslan

  4. Jun 13, 2024

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  5. Jul 2, 2024

    Passed: Electrical - Temporary Service

    Inspected by Gary Pitzer

  6. Jul 2, 2024

    Release to power company

    Inspected by Gary Pitzer

  7. Nov 4, 2025

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Gary Pitzer

  8. Dec 16, 2025

    Failed: Building - Slab

    Gate Locked, Please Have Open For Next Trip Please

    Inspected by Gary Pitzer

  9. Dec 17, 2025

    Passed: Building - Slab

    Sw Corner That Is To Be Used As Residence Has 2#5 Rebare In Footings Wire In Slab With Plastic, Storage Has Single #5 Bar With Wire In Slab And Plastic

    Inspected by Gary Pitzer

Documents