Permit Details

Permit Search

Permit

New Residential Construction

677 NW BELL LAKE CT
LAKE CITY, FL 32055

Permit #
000049885
Application #
64827
Status Completed
  1. Submitted Apr 8, 2024
  2. Issued May 21, 2024
  3. Expires Oct 13, 2025
  4. Completed May 14, 2025

Property

Parcel #
00186-008
Owner
Wehinger Joshua, Wehinger Lari
Acres
2.00
Subdivision
—
Zoning
A-3
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0260C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
2
Heated Area (Sqft)
2069
Total Area (Sqft)
3041
Building Height
25
Building Code Construction Type
IV
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0336
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Documents Required
  5. Zoning Review - Reviewed
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Documents Required
  10. Plan Review - Plumbing Approved
  11. Plan Review - Mechanical Approved
  12. Plan Review - Electrical Approved
  13. Plan Review - Building Approved
  14. Plan Review - Reviewed
  15. Final Review - Documents Required
  16. Final Review - Documents Required
  17. Final Review - Documents Required
  18. Final Review - Documents Required
  19. Final Review - Processing
  20. Final Review - Reviewed
  21. Final Review - Payment Needed
  22. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. Jun 3, 2024

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Jun 3, 2024

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Jun 14, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  4. Jun 24, 2024

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Jul 5, 2024

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  6. Jul 19, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    125 Psi On Water

    Inspected by Gary Pitzer

  7. Aug 14, 2024

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  8. Aug 20, 2024

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  9. Aug 20, 2024

    Passed: Building - Framing

    Inspected by Troy Crews

  10. Aug 20, 2024

    Passed: Electrical - 2nd Rough-In

    Complete Bath Fans And Smoke Detector

    Inspected by Troy Crews

  11. Sep 4, 2024

    Passed: Building - Insulation

    Inspected by Troy Crews

  12. Apr 16, 2025

    Passed: Building - Final

    Septic Release Rec'd-- Assessments Owed Prior To Co-- 5.7.25 Mg, Payment Rec'd 5.14.25

    Inspected by Troy Crews

  13. Apr 16, 2025

    Passed: Electrical - Permanent Power

    Need Septic Final

    Inspected by Troy Crews

  14. May 7, 2025

    Release to power company

    Rec'd Septic Release

    Inspected by Melissa Garber

  15. May 7, 2025

    Septic Release Inspection

    Inspected by Health Dept

  16. May 7, 2025

    Submitted Power Release through FPL Portal

    Inspected by Garber, Melissa

Documents