Permit Details

Permit Search

Permit

Storage Building

208 SW FABIAN WAY
LAKE CITY, FL 32024

Permit #
000049735
Application #
64631
Status Completed
  1. Submitted Mar 21, 2024
  2. Issued May 6, 2024
  3. Expires Feb 3, 2025
  4. Completed Aug 7, 2024

Property

Parcel #
03079-033
Owner
Milewski James Michael, Niquette Gloria Lynn
Acres
0.36
Subdivision
Shady Oaks Acres Unit 2
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Accessory Use
Finished floor requirement
Non-Habitable Structure
Fema map number
12023C0380C
Type of Structure
Storage Building
Commercial or Residential?
Residential
Total Area (Sqft)
600
Septic# (00-0000) or (X00-000)
24-0308
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setback Rear
10' (accessory)
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Storage
Occupancy Use Title
non habitable storage
Dev Permit #
F023-
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Building Height
10’
Building Length
25'
Building Width
24' with 12' lean to

Status & Review History

  1. Point Review - Reviewed
  2. Plan Review - Reviewed
  3. Zoning Review - Reviewed
  4. Final Review - Documents Required
  5. Final Review - Documents Required
  6. Final Review - Payment Needed
  7. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. Apr 30, 2024

    Septic Release Inspection

    Inspected by Health Dept

  2. May 22, 2024

    Failed: Building - Slab

    #5 Bar Is Required In The Footing Calls For Pest Control Termite Protection You Do Not See Any Documents On Site Permit Included

    Inspected by Matt Forsyth

  3. May 23, 2024

    Passed: Building - Slab

    Mono Slab 2#5 Wired On Chairs

    Inspected by Gary Pitzer

  4. Jun 5, 2024

    Cancelled: Building - Slab

    Inspected by Anthony Aslan

  5. Jun 6, 2024

    Passed: Building - Slab

    Poured

    Inspected by Gary Pitzer

  6. Aug 7, 2024

    Passed: Building - Final

    Inspected by Gary Pitzer