Permit Details

Permit Search

Permit

Roof Replacement or Repair

565 SW PHILLIPS CIR
LAKE CITY, FL 32024

Permit #
000049655
Application #
64889
Status Completed
  1. Submitted Apr 16, 2024
  2. Issued Apr 18, 2024
  3. Expires Jan 6, 2025
  4. Completed Jul 10, 2024

Property

Parcel #
02739-225
Owner
Turner Corina, Turner Clay W
Acres
0.49
Subdivision
Turkey Run
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0290D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
remove shingles and underlayment replace with metal roofing
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
1700
No. of Stories
1
Roof Pitch
2:12 to 4:12
Is the existing roof being removed?
Yes
Type of New Roofing Product
Metal
Florida Product Approval Number
36904.2
Product Manufacturer
Tri County Metals
Product Description
290 Gauge Ultra Rib
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Final Review - Corrections Needed
  5. Final Review - Payment Needed
  6. Permit Issued

Contractors

  • Phillip Richardson

    Southern Magnolia Builders, Llc

    License
    CCC13346444
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Apr 19, 2024

    Passed: Re-Roof - In Progress

    Underlayment Underlayment Confirmed

    Inspected by Matt Forsyth

  2. Jun 28, 2024

    Failed: Re-Roof - Final

    Need Pictures Of Ventilation Opening

    Inspected by Matt Forsyth

  3. Jul 10, 2024

    Passed: Re-Roof - Final

    Inspected by Matt Forsyth