Permit Details

Permit Search

Permit

New Residential Construction

295 NW SUGARCANE PL
LAKE CITY, FL 32055

Permit #
000049641
Application #
64536
Status Completed
  1. Submitted Mar 12, 2024
  2. Issued Apr 17, 2024
  3. Expires Sep 1, 2025
  4. Completed Mar 12, 2025

Property

Parcel #
01689-113
Owner
Bell Jeremy, Bell Wendy
Acres
4.94
Subdivision
Suwannee Hills
Zoning
A-3
Flood zone
X
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
12 INCHES ABOVE EXISTING GRADE NA
Document receieved
Yes
Fema map number
12023C0187D
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2302
Total Area (Sqft)
3420
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0286
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Reviewed
  2. Point Review - Documents Required
  3. Plan Review - Building Approved
  4. Plan Review - Electrical Approved
  5. Plan Review - Mechanical Approved
  6. Plan Review - Plumbing Approved
  7. Plan Review - Fuel/Gas Approved
  8. Plan Review - Reviewed
  9. Zoning Review - Reviewed
  10. Final Review - Documents Required
  11. Final Review - Documents Required
  12. Final Review - Reviewed
  13. Final Review - Payment Needed
  14. Permit Issued
  15. Final Review - Payment Needed

Contractors

  • Seth A Heitzman

    Seth Heitzman Construction,inc.

    License
    CBC1251065
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Caleb Laughlin

    Precision Exteriors Llc

    License
    CCC1327718
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance Expired.

  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Derrick L Williams

    Dl Williams Heating & Cooling Llc

    License
    CAC1816913
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor

Inspections

  1. Apr 25, 2024

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  2. Apr 25, 2024

    Release to power company

    Inspected by Troy Crews

  3. May 1, 2024

    Passed: Building - Footer

    Inspected by Troy Crews

  4. May 1, 2024

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  5. Jun 10, 2024

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Troy Crews

  6. Jun 10, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Waste Only

    Inspected by Troy Crews

  7. Jun 14, 2024

    Passed: Building - Slab

    Front Of House Lowest Grade Has 12 Inches Above Existing Grade Per. Engineer

    Inspected by Troy Crews

  8. Jul 22, 2024

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  9. Jul 22, 2024

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  10. Aug 14, 2024

    Passed: Building - Framing

    Inspected by Troy Crews

  11. Aug 14, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  12. Sep 10, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  13. Sep 10, 2024

    Passed: Mechanical - Rough In

    Make Sure Gas Supplier Does Final Pressure Test On Gas Piping Before Any Start Up

    Inspected by Troy Crews

  14. Sep 23, 2024

    Passed: Building - Insulation

    Inspected by Troy Crews

  15. Jan 17, 2025

    Rescheduled 1/21/2025:Electrical - Permanent Power

    Inspected by Troy Crews

  16. Jan 21, 2025

    Passed: Electrical - Permanent Power

    Need Septic Final

    Inspected by Troy Crews

  17. Feb 10, 2025

    Release to power company

    Inspected by Melissa Garber

  18. Feb 10, 2025

    Septic Release Inspection

    Inspected by Health Dept

  19. Mar 4, 2025

    Cancelled: Electrical - Permanent Power

    Inspected by Troy Crews

  20. Mar 5, 2025

    Passed: Building - Final

    Have Gas Supplier Do Final Pressure Test And Startup.

    Inspected by Troy Crews

  21. Mar 12, 2025

    Certificate-Release Certificate

    Inspected by Troy Crews

Documents