Permit Details

Permit Search

Permit

Storage Building

2268 NE BASCOM NORRIS DR
LAKE CITY, FL 32055

Permit #
000049624
Application #
64729
Status Completed
  1. Submitted Mar 28, 2024
  2. Issued Apr 15, 2024
  3. Expires Oct 7, 2025
  4. Completed Apr 10, 2025

Property

Parcel #
06892-010
Owner
Uscanga Jose F
Acres
1.34
Subdivision
—
Zoning
I
Flood zone
X
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0305D
Type of Structure
Storage Building
Commercial or Residential?
Commercial
Total Area (Sqft)
2016
Septic# (00-0000) or (X00-000)
x24-039
Setbacks Front
20'
Setback Side 1
15'
Setback Side 2
15'
Setback Rear
15'
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Storage
Occupancy Use Title
storage
Dev Permit #
F023-
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Building Height
12
Building Length
72
Building Width
28
Service Amps
200

Status & Review History

  1. City of Lake City Utilities Notified.
  2. Point Review - Printed-Online Application
  3. Zoning Review - Contact the Building Dept
  4. Zoning Review - Documents Required
  5. Zoning Review - Reviewed
  6. Plan Review - Building Approved
  7. Plan Review - Reviewed
  8. Final Review - Documents Required
  9. Final Review - Documents Required
  10. Final Review - Reviewed
  11. Final Review - Payment Needed
  12. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. Apr 12, 2024

    Septic Release Inspection

    Inspected by Health Dept

  2. Apr 26, 2024

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  3. Apr 26, 2024

    Release to power company

    Inspected by Troy Crews

  4. May 21, 2024

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Troy Crews

  5. Oct 8, 2024

    Rescheduled 10/9/2024:Electrical - 2nd Rough-In

    Inspected by Troy Crews

  6. Oct 9, 2024

    Rescheduled 10/11/2024:Electrical - 2nd Rough-In

    Inspected by Troy Crews

  7. Oct 10, 2024

    Rescheduled 10/10/2024:Electrical - 2nd Rough-In

    Inspected by Troy Crews

  8. Oct 10, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  9. Apr 10, 2025

    Passed: Building - Final

    Inspected by Troy Crews

  10. Apr 10, 2025

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews