Permit Details

Permit Search

Permit

Mobile Home

755 SW ROBERTS AVE
FORT WHITE, FL 32038

Permit #
000049611
Application #
64464
Status Completed
  1. Submitted Mar 14, 2024
  2. Issued Apr 12, 2024
  3. Expires Nov 12, 2024
  4. Completed May 16, 2024

Property

Parcel #
03999-006
Owner
Byrd Robin Delon Jr
Acres
3.80
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
32" ABOVE ADJACENT GROUND FOR ENTIRE PERIMETER
Fema map number
12023C0459C
Mobile Home is a:
Single Wide
Year Built
2024
Width (Ft.In)
16
Length (Ft.In)
80
Driveway access to home:
Existing Drive
Installation Decal #
108425
Special temporary use permit number:
STU240310
Septic #
24-0206
Setbacks Front
30'
Setback Side 1
25'
Setbacks Rear
25'
Dev Permit #
F023-
Setback Side 2
25'
Are you applying for a 5 year temporary permit?
Yes
Serial #
LOHGA30074396
Wind Zone?
2
Residential or Commercial Use?
Residential
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Plan Review - Reviewed
  5. Zoning Review - Corrections Needed
  6. Zoning Review - Corrections Needed
  7. Zoning Review - Reviewed
  8. Final Review - Documents Required
  9. Final Review - Reviewed
  10. Final Review - Payment Needed
  11. Permit Issued

Contractors

  • David Albright

    David Albright Mobile Home Svc Llc

    License
    IH1129420
    Title
    Mh Installer (ih)
    Role
    Contractor
  • Gary L Johnston

    Lightning R Services Llc

    License
    EC13012402
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Michael A Boland

    Ace A/c Of Ocala Llc

    License
    CAC1817716
    Title
    Cert Class B A/c
    Role
    Subcontractor

Inspections

  1. May 16, 2024

    Passed: Mobile Home - Mobile Home Set-Up Final

    Septic Needed

    Inspected by Matt Forsyth

  2. May 16, 2024

    Passed: Engineering - Setbacks

    Perimeter Of The House Looks Good Four Grade

    Inspected by Matt Forsyth

  3. Jun 5, 2024

    Septic Release Inspection

    Inspected by Health Dept

  4. Jun 6, 2024

    Release to power company

    Rec'd Septic

    Inspected by Matt Forsyth