Permit Details

Permit Search

Permit

Roof Replacement or Repair

229 SW ROYAL CT
LAKE CITY, FL 32024

Permit #
000049515
Application #
64709
Status Completed
  1. Submitted Mar 27, 2024
  2. Issued Mar 27, 2024
  3. Expires Oct 22, 2024
  4. Completed Apr 25, 2024

Property

Parcel #
03081-113
Owner
Harris Steven A, Harris Eugenie L
Acres
0.51
Subdivision
Kensington
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0380C
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
Remove existing shingle roofing material and replace any damaged decking. Install new architectural shingle roof.
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
5000
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10124.1
Other Roofing Product Type Not Listed
Midstates Asphalt Quik Felt Underlayment
Product Manufacturer
GAF
Product Description
Timberline UHDZ
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Unvented
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Titus Lea

    Certified Roofing Solutions Llc

    License
    CCC1326502
    Title
    Cert. Roofing
    Role
    Contractor

    County License & State License & Employees Workers Comp Expired.

Inspections

  1. Apr 5, 2024

    Passed: Re-Roof - In Progress

    Inspected by Matt Forsyth

  2. Apr 25, 2024

    Passed: Re-Roof - Final