Search pages and services on the county website.
Choose the colors you prefer.
Permit
1580 E DUVAL STLAKE CITY, FL 32055
This is an owner-builder project.
Passed: Fire - Fire Rated Wall
Framing Done In Order To Take Two Layes Each Side Up To Bottom Of Roof Deck
Inspected by Troy Crews
Passed: Building - Fire Rated Wall
Failed: Electrical - 2nd Rough-In
Need To Sleeve Service Wires To Panel With Metal Piping Extending 18 Inches Each Side Of Fire Wall And Sealed With Fire Foam
Inspected by Cpt. Shane Ovesterrt
Passed: Electrical - 2nd Rough-In
Metal Sleeves Installed On Wiring Thru Fire Wall
Passed: Plumbing/Gas - 1st Underground Rough–In
Waste Only
Rescheduled 6/25/2024:Plumbing/Gas - 2nd Rough-In
Failed: Plumbing/Gas - 2nd Rough-In
Building Locked Need Water Line Pressure Test Inspection
Passed: Plumbing/Gas - 2nd Rough-In
All Tubs Were Water Tested(5) Water Pressure Was Up On All Units(5)
Inspected by Matt Forsyth
All Lines Fire Foam Sealed
Passed: Electrical - Permanent Power
Need Septic Final
Release to power company
Inspected by Melissa Garber
Passed: Building - Final
Checked All Ground Fault Receptacle Smoke Detectors Etc.