Permit Details

Permit Search

Permit

Roof Replacement or Repair

209 SW MORNING GLORY DR
LAKE CITY, FL 32024

Permit #
000049365
Application #
63911
Status Completed
  1. Submitted Jan 18, 2024
  2. Issued Mar 6, 2024
  3. Expires Sep 3, 2024
  4. Completed Mar 7, 2024

Property

Parcel #
03023-505
Owner
Urrely Jarrod Joseph, Urrely Tarsis Zoraida
Acres
0.51
Subdivision
Rolling Meadows
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0289D
Type Roofing Job
Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
50 sq Re Roof 10/12 Pitch Shingles FL10674
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
50
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10674
Product Manufacturer
Owens Corning
Product Description
Shingles
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.;two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Ridge Vent
Flashing:
Replace with Step Flashing
Drip Edge:
Replace All
Valley Treatment:
New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Final Review - Corrections Needed
  5. Final Review - Corrections Needed
  6. Final Review - Corrections Needed
  7. Final Review - Corrections Needed
  8. Point Review - Reviewed
  9. Plan Review - Reviewed
  10. Zoning Review - Reviewed
  11. Final Review - Corrections Needed
  12. Final Review - Corrections Needed
  13. Final Review - Payment Needed
  14. Permit Issued

Contractors

  • Cecil D Williams

    Quality Labor Souce

    License
    CCC1332875
    Title
    Cert. Roofing
    Role
    Contractor

Inspections

  1. Mar 7, 2024

    Passed: Re-Roof - Final

    Pass Per Photos And Affidavit Only, Please For Your Next Permit, Be Advised We Require An Inprogress Inspection While Roof Project Is Being Done

    Inspected by Gary Pitzer