Permit Details

Permit Search

Permit

New Residential Construction

122 SW SCOTT PL
LAKE CITY, FL 32024

Permit #
000049350
Application #
63886
Status Completed
  1. Submitted Jan 16, 2024
  2. Issued Mar 4, 2024
  3. Expires Mar 11, 2025
  4. Completed Sep 16, 2024

Property

Parcel #
02853-419
Owner
Lev Joann T, Crowther Robert E
Acres
0.75
Subdivision
Russwood Estates Unit 4
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0290D
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2530
Total Area (Sqft)
3456
Building Height
24
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
24-0063
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified.
  4. Point Review - On Hold-Incomplete
  5. Point Review - Printed-Online Application
  6. Plan Review - Building Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Mechanical Approved
  9. Plan Review - Plumbing Approved
  10. Plan Review - Fuel/Gas Approved
  11. Plan Review - Reviewed
  12. Zoning Review - Reviewed
  13. Final Review - Processing
  14. Final Review - Documents Required
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Final Review - Payment Needed
  18. Final Review - Payment Needed

Contractors

  • Joann T Lev

    Exceptions Realty Llc

    License
    CRC1329719
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Mar 12, 2024

    Passed: Building - Footer

    Watch For Dowel Placement

    Inspected by Matt Forsyth

  2. Mar 12, 2024

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Mar 18, 2024

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  4. Mar 18, 2024

    Release to power company

    Inspected by Matt Forsyth

  5. Apr 16, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  6. Apr 23, 2024

    Passed: Building - Slab

    Inspected by Matt Forsyth

  7. May 28, 2024

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  8. May 28, 2024

    Passed: Building - Framing

    Structural Building Components Inspected Windows And Doors Not Installed

    Inspected by Matt Forsyth

  9. May 28, 2024

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  10. May 28, 2024

    Passed: Building - Strapping

    Keep An Eye On Nail Size Post Base

    Inspected by Matt Forsyth

  11. May 28, 2024

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  12. Jun 11, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Jun 11, 2024

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  14. Jun 11, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Tub Water Tested

    Inspected by Matt Forsyth

  15. Jun 11, 2024

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Matt Forsyth

  16. Jun 24, 2024

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  17. Jul 12, 2024

    Septic Release Inspection

    Inspected by Health Dept

  18. Jul 22, 2024

    Passed: Electrical - Permanent Power

    Inspected by Matt Forsyth

  19. Jul 22, 2024

    Release to power company

    Inspected by Matt Forsyth

  20. Sep 12, 2024

    Passed: Building - Final

    Fresh Air Makeup For Blower Door Test Confirmed

    Inspected by Matt Forsyth

  21. Sep 16, 2024

    Certificate-Release Certificate

    Inspected by Matt Forsyth

Documents