Roof Replacement or Repair
Permit
| Application #: | 64169 |
| Permit #: |
000049197 |
| Related Permit: |
|
| Submitted: | Monday, February 12, 2024 |
| Issued: | Monday, February 12, 2024 |
| Expires: | Friday, September 13, 2024 |
| Completed: | Friday, September 13, 2024 |
| Status: |
Completed |
| Septic Release? |
N/A |
Job Details
| Finished floor requirement |
|
| Fema map number |
12023C0380C |
| Type Roofing Job |
Re-Cover - New Material over Existing |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Overlay |
| Type of structure |
House |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
57 |
| No. of Stories |
1 |
| Roof Pitch |
4:12 or Greater |
| Is the existing roof being removed? |
Yes |
| Type of New Roofing Product |
Metal |
| Florida Product Approval Number |
FL28363-R1 |
| Product Manufacturer |
Deep South Metals |
| Product Description |
26 GA Metal |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Sealed roof decking options: (Must select an option.) |
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof. |
| Ventilation: |
Unvented |
| Flashing: |
Replace All |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |
Review Notes
| 2/12/2024 |
Application pending. |
| 2/12/2024 |
Application submitted by applicant. |
| 2/12/2024 |
Final Review - Payment Needed |
| 2/12/2024 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
Tristan J Hall J&m Residential Services Florida Division, Llc
|
CCC1331951 |
Cert. Roofing |
Contractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Failed: Re-Roof - In Progress |
Appears This Address Has A New Black Metal Roof Covering Without An In Progress Inspection, No Pictures On File, We Need To See Your Projects At The At The Time Work Is Being Done For In Progress Inspection |
Gary Pitzer |
4/5/2024 |
| Failed: Re-Roof - Final |
Need Picture Of Purlins, Or Installation Guide That Allows Direct Attachment To Deck |
Troy Crews |
9/10/2024 |
| Passed: Re-Roof - Final |
|
Troy Crews |
9/13/2024 |