Permit Details

Permit Search

Permit

New Residential Construction

672 NE INDIGO DR
LAKE CITY, FL 32055

Permit #
000048935
Application #
62837
Status Completed
  1. Submitted Oct 4, 2023
  2. Issued Jan 2, 2024
  3. Expires May 17, 2025
  4. Completed Nov 21, 2024

Property

Parcel #
04838-117
Owner
Ratliff Robert D, Ratliff Amy B
Acres
11.64
Subdivision
Osceola Plantations Unr
Zoning
A-3
Flood zone
A
District
1

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Special Flood Hazard Area
Finished floor requirement
Two feet above the Dirt road
Fema map number
12023C0215D
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1927
Total Area (Sqft)
3001
Building Height
25.4
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0790
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
300

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - On Hold-Incomplete
  4. Point Review - Email Sent
  5. Point Review - On Hold-Incomplete
  6. Point Review - Printed-Online Application
  7. Plan Review - Corrections Needed
  8. Plan Review - On Hold-Incomplete
  9. Plan Review - On Hold-Incomplete
  10. Plan Review - Corrections Needed
  11. Plan Review - Building Approved
  12. Plan Review - Electrical Approved
  13. Plan Review - Mechanical Approved
  14. Plan Review - Plumbing Approved
  15. Plan Review - Fuel/Gas Approved
  16. Plan Review - Reviewed
  17. Zoning Review - Corrections Needed
  18. Zoning Review - Reviewed
  19. Final Review - Reviewed
  20. Final Review - Contact the Building Dept
  21. Final Review - Reviewed
  22. Final Review - Payment Needed
  23. Final Review - Payment Needed
  24. Permit Issued

Contractors

  • Carrie Cason

    Stanley Crawford Construction Inc

    License
    CBC1254767
    Title
    Cert. Building
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Don C Bills Sr

    Hometown Plumbing Services Llc

    License
    CFC1428890
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Ralph W Laverdure

    Rwl Roofing Llc

    License
    CCC1328590
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Donald Davis

    High Springs Electric Inc

    License
    EC0002306
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Stephen M Brisbois

    Epic Ac Service (dba) Central Home Heating & Air Llc

    License
    CAC1819412
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

Inspections

  1. Nov 30, 2023

    Septic Release Inspection

    Inspected by Health Dept

  2. Jan 18, 2024

    Passed: Building - Footer

    10 By 20 With Two Number Five

    Inspected by Troy Crews

  3. Jan 18, 2024

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  4. Feb 6, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Dvw Only, No Clean Out On Outside At This Time

    Inspected by Gary Pitzer

  5. Feb 8, 2024

    Passed: Building - Slab

    Inspected by Troy Crews

  6. Mar 18, 2024

    Passed: Building - Wall Sheathing

    Inspected by Gary Pitzer

  7. Mar 18, 2024

    Failed: Building - Roof Decking

    Lots Of Shines ( Nails That Missed Truss Or Rafter)

    Inspected by Gary Pitzer

  8. Mar 18, 2024

    Failed: Building - Ext Strapping/Wall Sheathing

    Not Complete

    Inspected by Gary Pitzer

  9. Mar 18, 2024

    Failed: Building - Strapping

    Not Complete And Also No Framing Inspection

    Inspected by Gary Pitzer

  10. Mar 21, 2024

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Gary Pitzer

  11. Mar 21, 2024

    Passed: Building - Roof Decking

    Inspected by Gary Pitzer

  12. Mar 21, 2024

    Passed: Building - Strapping

    Inspected by Gary Pitzer

  13. Apr 25, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Gary Pitzer

  14. Apr 25, 2024

    Passed: Mechanical - Rough In

    Inspected by Gary Pitzer

  15. Apr 25, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Gary Pitzer

  16. Apr 25, 2024

    Passed: Building - Framing

    Inspected by Gary Pitzer

  17. May 2, 2024

    Passed: Building - Insulation

    Walls

    Inspected by Gary Pitzer

  18. Sep 16, 2024

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  19. Sep 16, 2024

    Release to power company

    Inspected by Troy Crews

  20. Nov 18, 2024

    Passed: Building - Final

    Cannot Closed Permit Or Release Certificate Of Occupancy Due To Missing Required Documents.

    Inspected by Gary Pitzer

  21. Nov 21, 2024

    Certificate-Release Certificate

    Inspected by Gary Pitzer

Documents