New Residential Construction
Permit
| Application #: | 62470 |
| Permit #: |
000048826 |
| Related Permit: |
|
| Submitted: | Tuesday, September 19, 2023 |
| Issued: | Monday, December 11, 2023 |
| Expires: | Monday, June 10, 2024 |
| Completed: | Monday, June 10, 2024 |
| Status: |
Completed |
| Septic Release? |
Yes |
Job Details
| Elevation regulation |
Minimum Requirement |
| Finished floor requirement |
One foot above the road |
| Fema map number |
12023C0490C |
| This is the construction of a |
Single Family Dwelling |
| Setbacks Front |
30' |
| Setback Side 1 |
25' |
| Setback Side 2 |
25' |
| Setbacks Rear |
25' |
| Stories |
1 |
| Heated Area (Sqft) |
1843 |
| Total Area (Sqft) |
2716 |
| Building Height |
9 |
| Building Code Construction Type |
V |
| Building Code Element |
B |
| Building Code Occupancy Types |
Residential |
| Occupancy Use Title |
single family dwelling |
| Building Code Edition |
2020 Florida Building Code 7th Edition and 2017 National Electrical Code |
| Septic# (00-0000) or (X00-000) |
23-0639 |
| Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Service Amps |
200 |
Review Notes
| 9/6/2023 |
Application pending. |
| 9/19/2023 |
Application submitted by applicant. |
| 9/25/2023 |
Point Review - Printed-Online Application |
| 9/28/2023 |
Plan Review - Corrections Needed |
| 9/28/2023 |
Plan Review - Building Approved |
| 9/28/2023 |
Plan Review - Electrical Approved |
| 9/28/2023 |
Plan Review - Mechanical Approved |
| 9/28/2023 |
Plan Review - Plumbing Approved |
| 9/28/2023 |
Plan Review - Fuel/Gas Approved |
| 9/28/2023 |
Plan Review - Reviewed |
| 10/9/2023 |
Zoning Review - Documents Required |
| 10/9/2023 |
Final Review - Documents Required |
| 10/24/2023 |
Zoning Review - Reviewed |
| 11/20/2023 |
Final Review - Documents Required |
| 12/7/2023 |
Final Review - Documents Required |
| 12/11/2023 |
Final Review - Email Sent |
| 12/11/2023 |
Final Review - Documents Required |
| 12/11/2023 |
Final Review - Processing |
| 12/11/2023 |
Final Review - Payment Needed |
| 12/11/2023 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
Jeffrey P Bokor Dwc Contracting Llc
|
CGC1517145 |
General Contractor |
Contractor |
James Butler Jr Butler Plumbing Of Gainesville Inc
|
CFC057960 |
Plumbing Contractor |
Subcontractor |
Jeffrey Bokor Dwc Contracting Llc
|
CCC1329756 |
Roofing Contractor |
Subcontractor |
Samuel L Roberts Air Ducks Inc
Liability Insurance & Workers Comp & Employees Workers Comp Expired. |
CAC1817288 |
Class "b" A/c |
Subcontractor |
Ryan C Beville Rbi Electrical Contracting Llc
|
EC13004236 |
Electrical Contractor |
Subcontractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Anthony Aslan |
1/11/2024 |
| Passed: Building - Monolithic Slab |
|
Anthony Aslan |
1/23/2024 |
| Passed: Engineering - Setbacks |
|
Anthony Aslan |
1/23/2024 |
| Passed: Building - Roof Decking |
|
Anthony Aslan |
2/8/2024 |
| Passed: Building - Strapping |
|
Anthony Aslan |
2/8/2024 |
| Passed: Building - Wall Sheathing |
|
Anthony Aslan |
2/8/2024 |
| Failed: Plumbing/Gas - 2nd Rough-In |
No Pressure On Piping |
Anthony Aslan |
2/20/2024 |
| Passed: Electrical - 2nd Rough-In |
One Box In Kitchen Not Made Up, Check At Mechanicial Rough |
Anthony Aslan |
2/20/2024 |
| Passed: Mechanical - Rough In |
|
Anthony Aslan |
2/22/2024 |
| Passed: Plumbing/Gas - 2nd Rough-In |
Tub Drop In, Shower Pan Good |
Anthony Aslan |
2/22/2024 |
| Passed: Plumbing/Gas - Tub Set/Shower Pan |
No Water In System |
Anthony Aslan |
2/22/2024 |
| Passed: Building - Insulation |
Walls Only |
Anthony Aslan |
2/27/2024 |
| Passed: Plumbing/Gas - 2nd Rough-In |
|
Anthony Aslan |
2/27/2024 |
| Passed: Electrical - Permanent Power |
Need Septic Release |
Anthony Aslan |
4/30/2024 |
| Release to power company |
Rec'd Septic |
Anthony Aslan |
5/14/2024 |
| Septic Release Inspection |
|
Health Dept |
5/14/2024 |
| Passed: Building - Final |
Locking Caps A/c |
Anthony Aslan |
6/10/2024 |