Permit Details

Permit Search

Permit

Roof Replacement or Repair

499 SW GALLANT LN
LAKE CITY, FL 32024

Permit #
000048620
Application #
63321
Status Completed
  1. Submitted Nov 9, 2023
  2. Issued Nov 9, 2023
  3. Expires Aug 13, 2024
  4. Completed Feb 15, 2024

Property

Parcel #
00350-003
Owner
Gonzalez Baldomero Jr, Gonzalez Janice Elaine
Acres
2.58
Subdivision
—
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0270C
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
4638
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL10124-R27
Product Manufacturer
GAF
Product Description
Architectural Shingles
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Use Existing
Valley Treatment:
New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Permit Issued

Contractors

  • Roger D Whiddon

    Whiddon Construction Co Inc

    License
    CCC1330273
    Title
    Roofing Contractor
    Role
    Contractor

Inspections

  1. Feb 12, 2024

    Passed: Re-Roof - In Progress

    Underlayment Complete

    Inspected by Matt Forsyth

  2. Feb 15, 2024

    Passed: Re-Roof - Final

    Inspected by Matt Forsyth