Permit Details

Permit Search

Permit

New Residential Construction

2260 SW ICHETUCKNEE AVE
LAKE CITY, FL 32024

Permit #
000048449
Application #
62897
Status Completed
  1. Submitted Oct 5, 2023
  2. Issued Oct 19, 2023
  3. Expires Jan 15, 2025
  4. Completed Jul 19, 2024

Property

Parcel #
00469-103
Owner
Robinson Joshua C, Robinson Jessica A
Acres
9.94
Subdivision
Shirley Gorospe Tract (division Of Land)
Zoning
ESA-2
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0370C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2000
Total Area (Sqft)
3104
Building Height
15
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0723
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Plan Review - Plumbing Approved
  4. Plan Review - Mechanical Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Building Approved
  7. Plan Review - Reviewed
  8. Zoning Review - Reviewed
  9. Final Review - Documents Required
  10. Final Review - Payment Needed
  11. Permit Issued

Contractors

  • Max L Bass

    B&b Homes New Home Builders Inc

    License
    RR282811195
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License Expired.

Inspections

  1. Dec 13, 2023

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Dec 13, 2023

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Jan 22, 2024

    Cancelled: Electrical - 1st Underground Rough–In

    Inspected by Melissa Garber

  4. Jan 22, 2024

    Cancelled: Electrical - Temporary Service

    Inspected by Melissa Garber

  5. Jan 22, 2024

    Cancelled: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Melissa Garber

  6. Jan 22, 2024

    Rescheduled 1/22/2024:Electrical - 1st Underground Rough–In

    Inspected by Melissa Garber

  7. Jan 22, 2024

    Rescheduled 1/22/2024:Electrical - Temporary Service

    Inspected by Melissa Garber

  8. Jan 22, 2024

    Rescheduled 1/22/2024:Plumbing/Gas - 1st Underground Rough–In

    Inspected by Melissa Garber

  9. Jan 22, 2024

    Rescheduled 1/22/2024:Building - Slab

    Inspected by Melissa Garber

  10. Jan 22, 2024

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  11. Jan 22, 2024

    Release to power company

    Inspected by Matt Forsyth

  12. Jan 22, 2024

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  13. Jan 22, 2024

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  14. Jan 26, 2024

    Failed: Building - Slab

    Perimeter Bar Needs To Be Tied Up Minimum Three Quarter Inch Clearance Plastic Needs To Be Cut Away From Web Holes In Places

    Inspected by Matt Forsyth

  15. Jan 30, 2024

    Passed: Building - Slab

    Gate Locked Contractor Showed Pictures To Cut Plastic Back At Time Of Pour.

    Inspected by Troy Crews

  16. Feb 15, 2024

    Passed: Building - Vertical Cells/Columns

    Just Need Spray Ticket And Picture For Porch Slabs Tommorrow.

    Inspected by Troy Crews

  17. Feb 16, 2024

    Passed: Building - Footer

    Inspected by Troy Crews

  18. Feb 16, 2024

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  19. Feb 16, 2024

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  20. Mar 6, 2024

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  21. Mar 6, 2024

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  22. Mar 6, 2024

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  23. Apr 9, 2024

    Passed: Building - Framing

    Inspected by Troy Crews

  24. Apr 9, 2024

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  25. Apr 9, 2024

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  26. Apr 9, 2024

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  27. Apr 9, 2024

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Troy Crews

  28. May 1, 2024

    Passed: Building - Insulation

    Inspected by Troy Crews

  29. Jul 11, 2024

    Septic Release Inspection

    Inspected by Health Dept

  30. Jul 15, 2024

    Passed: Electrical - Permanent Power

    Inspected by Matt Forsyth

  31. Jul 15, 2024

    Release to power company

    Inspected by Matt Forsyth

  32. Jul 19, 2024

    Passed: Building - Final

    Inspected by Gary Pitzer

Documents