Permit Details

Permit Search

Permit

New Residential Construction

352 SW BUTTERCUP DR
LAKE CITY, FL 32024

Permit #
000047778
Application #
61817
Status Completed
  1. Submitted Jul 10, 2023
  2. Issued Jul 27, 2023
  3. Expires Sep 1, 2024
  4. Completed Mar 5, 2024

Property

Parcel #
03023-538
Owner
Lev Peter L, Lev Joann T
Acres
0.49
Subdivision
Rolling Meadows
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
108'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0289D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1841
Total Area (Sqft)
2644
Building Height
23
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-1037
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified
  4. Point Review - Printed-Online Application
  5. Point Review - Reviewed
  6. Plan Review - Building Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Mechanical Approved
  9. Plan Review - Plumbing Approved
  10. Plan Review - Fuel/Gas Approved
  11. Plan Review - Reviewed
  12. Zoning Review - Reviewed
  13. Final Review - Processing
  14. Final Review - Reviewed
  15. Final Review - Payment Needed
  16. Permit Issued

Contractors

  • Joann T Lev

    Exceptions Realty Llc

    License
    CRC1329719
    Title
    Cert. Residential
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Dana D Johnson

    Mac Johnson Roofing Inc Dba Gulf Coast Metal Roofing

    License
    CCC1325497
    Title
    Cert Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance Expired.

  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. Aug 16, 2023

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Aug 16, 2023

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Sep 1, 2023

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  4. Sep 1, 2023

    Release to power company

    Inspected by Matt Forsyth

  5. Sep 22, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  6. Sep 26, 2023

    Failed: Building - Slab

    Plans Call For Wwm Supported 36" Oc

    Inspected by Matt Forsyth

  7. Oct 23, 2023

    Passed: Building - Framing

    Windows And Doors Not Installed Yet

    Inspected by Matt Forsyth

  8. Oct 23, 2023

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  9. Oct 23, 2023

    Passed: Building - Strapping

    Inspected by Matt Forsyth

  10. Oct 23, 2023

    Passed: Building - Wall Sheathing

    Windstorm Sheathing

    Inspected by Matt Forsyth

  11. Nov 2, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Nov 2, 2023

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  13. Nov 2, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Nov 2, 2023

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Tubd Water Tested

    Inspected by Matt Forsyth

  15. Nov 13, 2023

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  16. Dec 19, 2023

    Passed: Electrical - Permanent Power

    Septic Needed

    Inspected by Matt Forsyth

  17. Dec 21, 2023

    Release to power company

    Inspected by Melissa Garber

  18. Dec 21, 2023

    Septic Release Inspection

    Inspected by Health Dept

  19. Mar 5, 2024

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents