Permit Details

Permit Search

Permit

New Residential Construction

359 SW HEATHRIDGE DR
LAKE CITY, FL 32024

Permit #
000047506
Application #
61473
Status Completed
  1. Submitted Jun 7, 2023
  2. Issued Jun 20, 2023
  3. Expires Sep 15, 2024
  4. Completed Mar 19, 2024

Property

Parcel #
02438-106
Owner
Twentyeight Fourteen Llc,
Acres
0.50
Subdivision
Emerald Cove Phase 1
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
103'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0280D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
20'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
20' (easement)
Stories
1
Heated Area (Sqft)
1702
Total Area (Sqft)
2433
Building Height
18
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0372
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Plan Review - Corrections Needed
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Fuel/Gas Approved
  9. Plan Review - Reviewed
  10. Zoning Review - Reviewed
  11. Final Review - Processing
  12. Final Review - Reviewed
  13. Final Review - Payment Needed
  14. Permit Issued
  15. Final Review - Payment Needed
  16. Final Review - Payment Needed
  17. Final Review - Payment Needed

Contractors

  • Anthony George,jr.

    George Construction Llc

    License
    CGC016583
    Title
    General Contractor
    Role
    Contractor

    Workers Comp Expired.

  • Charles R Sanford

    Energy Electric Inc

    License
    EC0000175
    Title
    Cert. Electrical
    Role
    Subcontractor

    County License & State License Expired.

  • Harry D Moseley Sr

    Harrys Heating & Air Conditioning Inc

    License
    RA0030316
    Title
    Class A A/c Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor

Inspections

  1. Jul 12, 2023

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Jul 12, 2023

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Aug 23, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  4. Sep 6, 2023

    Passed: Building - Slab

    Inspected by Matt Forsyth

  5. Oct 18, 2023

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  6. Nov 21, 2023

    Passed: Building - Framing

    Inspected by Troy Crews

  7. Nov 21, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  8. Nov 21, 2023

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  9. Nov 21, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  10. Nov 28, 2023

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  11. Jan 24, 2024

    Septic Release Inspection

    Inspected by Health Dept

  12. Jan 30, 2024

    Cancelled: Electrical - Permanent Power

    Inspected by Melissa Garber

  13. Jan 30, 2024

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  14. Jan 30, 2024

    Release to power company

    Inspected by Troy Crews

  15. Jan 30, 2024

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  16. Jan 30, 2024

    Release to power company

    Inspected by Troy Crews

  17. Feb 5, 2024

    Release to power company

    Meter Socket Changed

    Inspected by Troy Crews

  18. Feb 9, 2024

    Passed: Electrical - Permanent Power

    Meter Combo Changed Again

    Inspected by Troy Crews

  19. Feb 9, 2024

    Release to power company

    Inspected by Troy Crews

  20. Mar 19, 2024

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents