Permit Details

Permit Search

Permit

Storage Building

160 SW ORANGE BLOSSOM CT
LAKE CITY, FL 32025

Permit #
000046955
Application #
60531
Status Completed
  1. Submitted Mar 21, 2023
  2. Issued Apr 13, 2023
  3. Expires Feb 6, 2024
  4. Completed Aug 10, 2023

Property

Parcel #
02941-126
Owner
Marshall Timothy Wayne, Marshall Wiwik
Acres
0.67
Subdivision
Southern Landings Aviation
Zoning
RSF-2
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Accessory Use
Finished floor requirement
Non-Habitable Structure
Fema map number
12023C0293D
In floodway
N
Type of Structure
Other
Commercial or Residential?
Residential
Total Area (Sqft)
2000
Septic# (00-0000) or (X00-000)
21-0801
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setback Rear
15'
Building Code Construction Type
III
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
hanger
Dev Permit #
F023-
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Building Height
21'
Building Length
50'
Building Width
40'

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Fuel/Gas Approved
  9. Plan Review - Reviewed
  10. Zoning Review - Reviewed
  11. Final Review - Reviewed
  12. Final Review - Reviewed
  13. Final Review - Payment Needed
  14. Final Review - Payment Needed
  15. Permit Issued

Contractors

  • Bryan Zecher

    Bryan Zecher Construction Inc

    License
    CBC054575
    Title
    Cert.building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Robert Ogles

    Ogles Roofing & Construction Llc

    License
    CCC1328699
    Title
    Cert Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Donald R Hollingsworth

    Holly Electric Inc

    License
    EC13005429
    Title
    Electrical
    Role
    Subcontractor
  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Mar 21, 2023

    Septic Release Inspection

    Inspected by Health Dept

  2. May 9, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Need Compaction Test Done

    Inspected by Matt Forsyth

  3. May 17, 2023

    Passed: Building - Slab

    Inspected by Matt Forsyth

  4. Jun 13, 2023

    Passed: Building - Ext Strapping/Wall Sheathing

    Need 24" Gable Strapping

    Inspected by Matt Forsyth

  5. Jun 13, 2023

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  6. Jun 21, 2023

    Passed: Building - Framing

    Inspected by Troy Crews

  7. Aug 10, 2023

    Passed: Building - Final

    Label Breakers. Item Addressed

    Inspected by Matt Forsyth