Permit Information

New Residential Construction Permit

Address 693 SW BARNEY ST
HIGH SPRINGS, FL 32643
Parcel #: 09889-014
Acres:10.10
Owner:Otero Michael F, Otero Diane J
Subdivision:Trinkner Farms Unr
Zoning:A-3
Flood Zone:X
District:4
Application #:59057
Permit #: 000046607
Related Permit:
Submitted:Monday, February 13, 2023
Issued:Tuesday, February 28, 2023
Expires:Friday, January 12, 2024
Completed:Friday, January 12, 2024
Status: Completed
Septic Release? Yes

Notes

MFE= 1' ABOVE THE ROAD

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0480C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1608
Total Area (Sqft) 2472
Building Height 30
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0879
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200

Review Notes

2/13/2023 Point Review - Received-Hard Copy Application
2/23/2023 Plan Review - Building Approved
2/23/2023 Plan Review - Electrical Approved
2/23/2023 Plan Review - Mechanical Approved
2/23/2023 Plan Review - Plumbing Approved
2/23/2023 Plan Review - Fuel/Gas Approved
2/23/2023 Plan Review - Reviewed
2/27/2023 Zoning Review - Reviewed
2/28/2023 Final Review - Reviewed
2/28/2023 Permit Issued
11/27/2023 Final Review - Payment Needed

Contractors

Name / Business License Title Role
Matthew A Erkinger,sr.
Erkinger Construction Group
County License & State License Expired.
CRC1330825 Residential Contractor Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Richard C Register
Register's Heating & Air Conditioning,inc.
County License & State License & Liability Insurance Expired.
CAC041267 Class B Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Wallace W Powell
Powell & Sons Roofing,inc.
County License & State License Expired.
CCC057307 Roofing Contractor Subcontractor

Inspections

Inspection Notes Performed By Date
Passed: Building - Footer Anthony Aslan 3/2/2023
Passed: Engineering - Setbacks Anthony Aslan 3/2/2023
Passed: Electrical - Temporary Service Anthony Aslan 3/13/2023
Release to power company Anthony Aslan 3/13/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 4/6/2023
Passed: Building - Slab Anthony Aslan 4/19/2023
Passed: Building - Wall Sheathing Partial, Gables Not Complete sheating Sheet Does Not Go From Top Of Top Plate Refer To Drawings Anthony Aslan 6/1/2023
Failed: Building - Roof Decking Spoke With Framer On Site On What To Cover, Roof Decking Not. Complete Anthony Aslan 6/1/2023
Passed: Building - Roof Decking Anthony Aslan 6/8/2023
Passed: Building - Framing Loose Rods Buy Garage And Buy Hall Bath Recheck It Installation Anthony Aslan 7/25/2023
Passed: Building - Strapping Anthony Aslan 7/25/2023
Passed: Electrical - 2nd Rough-In Anthony Aslan 7/25/2023
Passed: Mechanical - Rough In Insulation Missing On Some Boots And Need To Pull Off Insulation Backing On Other Boots Recheck It Insulation Anthony Aslan 7/25/2023
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 7/25/2023
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 7/25/2023
Passed: Building - Insulation Spray Foam Anthony Aslan 8/14/2023
Release to power company Melissa Garber 11/28/2023
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 11/28/2023
Septic Release Inspection Septic Rec'd Health Dept 11/28/2023
Failed: Building - Final Need Blower Door need Final Termite no Disconnect At Ahu disconnect Behind Condenser a/c Refrigerant Piping Out Side Not Uv Protective Type no Disconnect At Water Heater Anthony Aslan 12/28/2023
Passed: Building - Final No Disconnect On Water Heater Anthony Aslan 1/12/2024

Documents

File Name Date File Size
Lidar 56457 2022-11-03 11.08.40.565.pdf 2025.07.05 191.60kB
Manual J Forms 56457 2022-09-26 14.30.08.458.pdf 2025.07.05 70.42kB
Recorded Notice Of Commencement 20221004 092347.pdf 2025.07.05 258.79kB
Energy Code Forms 56457 2022-09-26 14.30.08.755.pdf 2025.07.05 411.61kB
161 Sw Winthrop Pl.pdf 2025.07.04 202.12kB
Owner Disclosure Statement 20221004 092448.pdf 2025.07.04 661.71kB
Residential Or Commercial Checklist 20221011 213807.pdf 2025.07.04 677.25kB
Subcontractor Form 20230303 212115.pdf 2025.07.04 235.99kB
Kremser Eh.pdf 2025.07.04 1.00MB
Property Appraiser Parcel Details Printed Page 20220914 132810.pdf 2025.07.04 1,022.89kB
Structural Engineering And Wind Load Calculations 20220914 131610.pdf 2025.07.04 4.06MB
Owner And Contractor Signature Page.pdf 2025.06.22 86.76kB
Original Permit 20221107.pdf 2025.06.22 50.18kB
Truss Layout.pdf 2025.06.22 61.94kB
Kremser Jan 24, 2024 2024-01-24 14.33.45.948.pdf 2025.06.22 296.00kB
Certificate Of Occupancy 20240516.pdf 2024.05.16 68.88kB
Blower Door Test Results 20240129 180633.pdf 2024.01.29 238.16kB
Termite Certificate_final 20240129 180242.pdf 2024.01.29 223.76kB
Power Release-electrical-permanent Power 20240122.pdf 2024.01.22 38.91kB
Subcontractor Form 20221004 191510.pdf 2023.12.23 204.55kB
Site Plan 20221024 143835.pdf 2023.12.23 197.75kB
Letter For Plans.pdf 2023.12.23 10.43kB
Recorded Deed 20220914 115342.pdf 2023.12.23 118.39kB
Product Approval Code Specifications Form 20221011 154108.pdf 2023.12.23 176.39kB
Architectural Plans 20220914 132403.pdf 2023.12.23 1.35MB
Truss Engineering 20220920 163520.pdf 2023.12.23 1,002.42kB
Termite Treatment_initial 20230303 212449.pdf 2023.12.23 245.60kB
Reviewed Truss Engineering 56457 2022-09-26 14.26.35.28.pdf 2023.12.23 1.11MB

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.