Permit Details

Permit Search

Permit

Roof Replacement or Repair

176 SW PETER COYLE CT
LAKE CITY, FL 32025

Permit #
000046571
Application #
59097
Status Completed
  1. Submitted Feb 21, 2023
  2. Issued Feb 22, 2023
  3. Expires Sep 5, 2023
  4. Completed Mar 9, 2023

Property

Parcel #
02939-123
Owner
Hilbert Tonya R
Acres
0.64
Subdivision
Creekside
Zoning
RSF-2
Flood zone
X
District
5

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0291D
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
41
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
5444.1
Product Manufacturer
CertainTeed
Product Description
Landmark series
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation:
Off-ridge Vent
Flashing:
Replace All
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Final Review - Payment Needed
  4. Final Review - Corrections Needed
  5. Final Review - Payment Needed
  6. Permit Issued

Contractors

  • Jeffrey Bokor

    Dwc Contracting Llc

    License
    CCC1329756
    Title
    Roofing Contractor
    Role
    Contractor

    Liability Insurance Expired.

Inspections

  1. Mar 3, 2023

    Passed: Re-Roof - In Progress

    Roof Is Complete At In Progress Inspection. Please Provide Adequate Photos For Roof. In The Future We Need To See In Progress Inspection Final Is Not Completeuntil We See Pictures.

    Inspected by Gary Pitzer

  2. Mar 6, 2023

    Failed: Re-Roof - Final

    The One Photo Received Is Inadaquate ,please Provide More Detailed Pictures

    Inspected by Gary Pitzer

  3. Mar 8, 2023

    Cancelled: Re-Roof - Final

    Inspected by Gary Pitzer

  4. Mar 9, 2023

    Rescheduled 3/9/2023:Re-Roof - Final

    Inspected by Melissa Garber

  5. Mar 9, 2023

    Passed: Re-Roof - Final

    Final Per Photos, Roof Covered At In Progress

    Inspected by Gary Pitzer