Permit Details

Permit Search

Permit

New Residential Construction

1432 SE COUNTY ROAD 349
LAKE CITY, FL 32025

Permit #
000046428
Application #
57347
Status Completed
  1. Submitted Dec 6, 2022
  2. Issued Feb 2, 2023
  3. Expires Mar 25, 2024
  4. Completed Sep 28, 2023

Property

Parcel #
09400-006
Owner
Reeves Brandon W
Acres
10.11
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
12" ABOVE HIGHIEST ADJACENT GRADE
Fema map number
12023C0415C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2060
Total Area (Sqft)
3188
Building Height
25
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
23-0029
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - On Hold-Incomplete
  4. Point Review - Printed-Online Application
  5. Point Review - Reviewed
  6. Plan Review - Building Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Mechanical Approved
  9. Plan Review - Plumbing Approved
  10. Plan Review - Fuel/Gas Approved
  11. Plan Review - Reviewed
  12. Zoning Review - Corrections Needed
  13. Zoning Review - Reviewed
  14. Final Review - Documents Required
  15. Final Review - Documents Required
  16. Final Review - Reviewed
  17. Final Review - Payment Needed
  18. Permit Issued

Contractors

  • Matthew Hentzelman

    Trademark Construction Group Inc.

    License
    CGC1514780
    Title
    General Contractor
    Role
    Contractor

    County License & State License Expired.

  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor
  • Michael Towne

    Towne Construction Group

    License
    CCC1330125
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • David P Wood

    Wood's Electrical Services Inc

    License
    EC13002213
    Title
    Electrical Contractor
    Role
    Subcontractor
  • David E Hall

    David Hall's Air Cond & Heating Svc,inc.

    License
    CAC057424
    Title
    Class B A/c Contractor
    Role
    Subcontractor

    Workers Comp Expired.

Inspections

  1. Feb 8, 2023

    Passed: Building - Footer

    Inspected by Anthony Aslan

  2. Feb 8, 2023

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  3. Mar 2, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Drains And Waterlines Only, Water Had 125psi

    Inspected by Gary Pitzer

  4. Mar 7, 2023

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  5. Mar 7, 2023

    Release to power company

    Inspected by Anthony Aslan

  6. Mar 15, 2023

    Passed: Building - Slab

    Inspected by Troy Crews

  7. Apr 5, 2023

    Failed: Building - Roof Decking

    Missing Nails

    Inspected by Anthony Aslan

  8. Apr 5, 2023

    Failed: Building - Wall Sheathing

    Missing Nails

    Inspected by Anthony Aslan

  9. Apr 10, 2023

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  10. Apr 10, 2023

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  11. May 17, 2023

    Passed: Building - Framing

    Inspected by Anthony Aslan

  12. May 17, 2023

    Passed: Electrical - 2nd Rough-In

    Kitchen Metal Box No Gronding Screw

    Inspected by Anthony Aslan

  13. May 17, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  14. May 17, 2023

    Passed: Mechanical - Rough In

    No Access To Dryer Boost, Truss Gang Plates On Dryer Need Nail Plates no Exhaust Fans Connected

    Inspected by Anthony Aslan

  15. Jun 2, 2023

    Passed: Building - Insulation

    Inspected by Gary Pitzer

  16. Aug 1, 2023

    Passed: Electrical - Permanent Power

    Ok For Service Release To Line Side Only, No Load

    Inspected by Gary Pitzer

  17. Aug 1, 2023

    Release to power company

    Inspected by Gary Pitzer

  18. Aug 7, 2023

    Septic Release Inspection

    Inspected by Health Dept

  19. Sep 27, 2023

    Passed: Building - Final

    No Locking Caps On A/c insulation On A/c Lines Outside Not Uv Protective Material a/c Chase Pipe No Sealed

    Inspected by Anthony Aslan

  20. Sep 28, 2023

    Certificate-Release Certificate

    Recv'd Pictures

    Inspected by Anthony Aslan

Documents