Permit Details

Permit Search

Permit

Roof Replacement or Repair

170 NW SILVER GLN
LAKE CITY, FL 32055

Permit #
000046407
Application #
58847
Status Completed
  1. Submitted Jan 26, 2023
  2. Issued Jan 31, 2023
  3. Expires Sep 3, 2023
  4. Completed Mar 7, 2023

Property

Parcel #
02365-111
Owner
170 Nw Silver Glen Llc
Acres
0.60
Subdivision
Oak Hamlet
Zoning
RSF-2
Flood zone
A
District
3

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0280D
Type Roofing Job
Replacement - Tear off Existing and Replace
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
29
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
Yes
Type of New Roofing Product
Asphalt Shingles
Florida Product Approval Number
FL18355_R5_II
Product Manufacturer
Tamko
Product Description
ASTM D3462 asphalt shingles and hip and ridge shingles
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City Utilities Notified
  4. Point Review - Processing
  5. Final Review - Documents Required
  6. Final Review - Documents Required
  7. Final Review - Documents Required
  8. Final Review - Documents Required
  9. Final Review - Reviewed
  10. Final Review - Payment Needed
  11. Permit Issued

Contractors

  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Contractor

Inspections

  1. Mar 2, 2023

    Passed: Re-Roof - In Progress

    Old Roof Removed,dryer In Waiting On Shingles. Be Sure To Take Pictures On Roof Vent Openings

    Inspected by Gary Pitzer

  2. Mar 7, 2023

    Passed: Re-Roof - Final

    Brown To Tan Dem. Shingle Roof Covering, New Trim, Boots, Vents, Ridge Vents

    Inspected by Gary Pitzer