Permit Information

New Residential Construction Permit

Address 106 SW GUSTY GLN
LAKE CITY, FL 32025
Parcel #: 08944-019
Acres:10.65
Owner:Mcdaniel Paul, Mcdaniel Leslie
Subdivision:Hillcrest Unr
Zoning:A-3
Flood Zone:X
District:4
Application #:57358
Permit #: 000046328
Related Permit:
Submitted:Wednesday, December 7, 2022
Issued:Monday, January 23, 2023
Expires:Monday, November 6, 2023
Completed:Monday, November 6, 2023
Status: Completed
Septic Release? Yes

Notes

MFE - 1' ABOVE THE ROAD

Job Details

Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0403C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 2
Heated Area (Sqft) 3953
Total Area (Sqft) 5265
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-1003
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Review Notes

12/7/2022 Application pending.
12/7/2022 Application submitted by applicant.
12/7/2022 Point Review - On Hold-Incomplete
12/14/2022 Point Review - Printed-Online Application
12/14/2022 Point Review - Reviewed
1/5/2023 Plan Review - Documents Required
1/9/2023 Plan Review - Documents Required
1/17/2023 Plan Review - Plumbing Approved
1/17/2023 Plan Review - Mechanical Approved
1/17/2023 Plan Review - Electrical Approved
1/17/2023 Plan Review - Building Approved
1/17/2023 Plan Review - Reviewed
1/17/2023 Zoning Review - Reviewed
1/19/2023 Final Review - Reviewed
1/20/2023 Final Review - Reviewed
1/23/2023 Permit Issued
7/5/2023 Point Review - Reviewed

Contractors

Name / Business License Title Role
Leslie R Mcdaniel
Reed Mcdaniel Construction Inc
CBC1255787 Cert. Building Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
Richard M Touchstone
Touchstone Heating & Air Inc
Liability Insurance & Workers Comp Expired.
CAC058099 Class B A/c Contractor Subcontractor
Paul R Mcdaniel
Reed Mcdaniel Construction Inc Dba Reed Roofing
Workers Comp Expired.
CCC1330719 Cert. Roofing Subcontractor

Inspections

Inspection Notes Performed By Date
Cancelled: Engineering - Setbacks Gary Pitzer 2/8/2023
Passed: Building - Footer Dug Footer With 3 Rebar, Electric Bond To Rebar Gary Pitzer 2/8/2023
Passed: Electrical - 1st Underground Rough–In Several Floor Boxes And Other Conduits Under Slab Gary Pitzer 3/9/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Waste Drain With 5+ft Water Column, All Drain To Back Right Corner From The Front Of House.no Water System Install At This Time Gary Pitzer 3/9/2023
Passed: Building - Slab Gary Pitzer 3/17/2023
Passed: Building - Framing Gary Pitzer 4/20/2023
Failed: Mechanical - Rough In Not Complete For Inspection Gary Pitzer 5/19/2023
Failed: Plumbing/Gas - 2nd Rough-In Not Complete For Inspection Gary Pitzer 5/19/2023
Failed: Electrical - 2nd Rough-In Work Not Complete For Inspection Gary Pitzer 5/19/2023
Passed: Electrical - 2nd Rough-In Gary Pitzer 5/30/2023
Passed: Mechanical - Rough In Gary Pitzer 5/30/2023
Passed: Plumbing/Gas - 2nd Rough-In Gary Pitzer 5/30/2023
Passed: Building - Insulation Roof Foamed,walls Battted Gary Pitzer 6/7/2023
Failed: Building - Lath/Stucco Stucco Does Not Meet Approved Siding Per Plan, Waiting On Product Approval Info For Siding Being Installed To Complete Inspection Gary Pitzer 6/28/2023
Passed: Building - Lath/Stucco What Is Installed Appears Complete At This Stage Gary Pitzer 7/6/2023
Failed: Electrical - Permanent Power Need Final Septic, Drive Culvert? Gary Pitzer 10/27/2023
Septic Release Inspection Health Dept 10/27/2023
Release to power company Melissa Garber 10/30/2023
Passed: Electrical - Permanent Power Private Drive Gary Pitzer 10/30/2023
Release to power company Gary Pitzer 10/30/2023
Passed: Building - Final Gary Pitzer 11/6/2023

Documents

File Name Date File Size

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.