Permit Details

Permit Search

Permit

New Residential Construction

8803 SE COUNTY ROAD 245
LAKE CITY, FL 32025

Permit #
000045896
Application #
56749
Status Completed
  1. Submitted Oct 18, 2022
  2. Issued Nov 10, 2022
  3. Expires Nov 22, 2023
  4. Completed May 26, 2023

Property

Parcel #
09218-003
Owner
Johns Lonnie R Iii
Acres
10.01
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0405C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1928
Total Area (Sqft)
2287
Building Height
22
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0695
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Plan Review - Corrections Needed
  6. Plan Review - Building Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Mechanical Approved
  9. Plan Review - Plumbing Approved
  10. Plan Review - Fuel/Gas Approved
  11. Plan Review - Reviewed
  12. Zoning Review - Reviewed
  13. Final Review - Reviewed
  14. Final Review - Reviewed
  15. Final Review - Payment Needed
  16. Permit Issued
  17. Plan Review - Reviewed
  18. Final Review - Payment Needed

Contractors

  • William B Scott

    William Scott Construction,inc.

    License
    CBC1250835
    Title
    Building Contractor
    Role
    Contractor

    County License & State License Expired.

  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Robert Jarvis

    Jarvis Heat And Air Llc

    License
    CAC1816766
    Title
    Class "b" A/c
    Role
    Subcontractor

    County License & State License Expired.

  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor

Inspections

  1. Nov 30, 2022

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  2. Nov 30, 2022

    Release to power company

    Inspected by Anthony Aslan

  3. Jan 19, 2023

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  4. Jan 27, 2023

    Failed: Building - Footer

    Plans Show Stem Wall Construction No Option For Mono Foundation. need Compaction Test

    Inspected by Anthony Aslan

  5. Jan 27, 2023

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  6. Jan 31, 2023

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  7. Jan 31, 2023

    Passed: Building - Footer

    Need Compaction Test (recv'd)

    Inspected by Anthony Aslan

  8. Feb 28, 2023

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Anthony Aslan

  9. Feb 28, 2023

    Passed: Building - Strapping

    Inspected by Anthony Aslan

  10. Feb 28, 2023

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  11. Feb 28, 2023

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  12. Feb 28, 2023

    Failed: Building - Framing

    Need Letter Engineering Calls For 3x3 Washers, 2x2 Washers Are Installed.

    Inspected by Anthony Aslan

  13. Mar 28, 2023

    Failed: Electrical - 2nd Rough-In

    Insulation Needs To Be Removed

    Inspected by Anthony Aslan

  14. Mar 28, 2023

    Failed: Mechanical - Rough In

    Insulation Needs To Be Removed, Exhaust Fans Not Installed

    Inspected by Anthony Aslan

  15. Mar 28, 2023

    Failed: Plumbing/Gas - 2nd Rough-In

    Insulation Needs To Be Removed

    Inspected by Anthony Aslan

  16. Mar 28, 2023

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Anthony Aslan

  17. Mar 30, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  18. Mar 30, 2023

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  19. Mar 30, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  20. May 19, 2023

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  21. May 19, 2023

    Passed: Electrical - Permanent Power

    Need Sptic Release, Waiting On Letter From Carol For Washers

    Inspected by Anthony Aslan

  22. May 22, 2023

    Release to power company

    Inspected by Melissa Garber

  23. May 22, 2023

    Septic Release Inspection

    Inspected by Health Dept

  24. May 23, 2023

    Cancelled: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  25. May 23, 2023

    Cancelled: Mechanical - Rough In

    Inspected by Troy Crews

  26. May 23, 2023

    Cancelled: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  27. May 25, 2023

    Cancelled: Electrical - Permanent Power

    Inspected by Troy Crews

  28. May 26, 2023

    Passed: Building - Final

    Recv'd Pictures

    Inspected by Anthony Aslan

Documents