Permit Details

Permit Search

Permit

New Residential Construction

142 SW ARROWBEND DR
LAKE CITY, FL 32024

Permit #
000045796
Application #
56025
Status Completed
  1. Submitted Aug 12, 2022
  2. Issued Oct 27, 2022
  3. Expires Nov 15, 2023
  4. Completed May 19, 2023

Property

Parcel #
03114-138
Owner
Cameron Tolar, Ariel Tolar
Acres
0.49
Subdivision
Cannon Creek Place
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
95.50'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0293D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1525
Total Area (Sqft)
2119
Building Height
20
Building Code Construction Type
IV
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0835
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Documents Required
  5. Plan Review - Corrections Needed
  6. Plan Review - Corrections Needed
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Plan Review - Corrections Needed
  10. Plan Review - Corrections Needed
  11. Plan Review - Documents Required
  12. Plan Review - Documents Required
  13. Plan Review - Corrections Needed
  14. Plan Review - Documents Required
  15. Plan Review - Documents Required
  16. Plan Review - Documents Required
  17. Plan Review - Documents Required
  18. Plan Review - Documents Required
  19. Plan Review - Building Approved
  20. Plan Review - Electrical Approved
  21. Plan Review - Mechanical Approved
  22. Plan Review - Plumbing Approved
  23. Plan Review - Fuel/Gas Approved
  24. Plan Review - Reviewed
  25. Zoning Review - Reviewed
  26. Final Review - Reviewed
  27. Final Review - Reviewed
  28. Final Review - Payment Needed
  29. Permit Issued
  30. Final Review - Payment Needed

Contractors

  • Bradley Franks

    Bradley Franks Construction Llc

    License
    RG291103874
    Title
    General Contractor
    Role
    Contractor

    County License & State License & Workers Comp Expired.

  • Oscar Gray

    Dependable Heating A/c & Electrical Contractor

    License
    EC0001471
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Anthony R Franks

    Lane Heating & Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • John D Williams

    John Williams Plumbing Inc

    License
    CFC056961
    Title
    Plumbing Contractor
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Oct 31, 2022

    Failed: Building - Footer

    Need Permit Posted And Noc

    Inspected by Matt Forsyth

  2. Oct 31, 2022

    Cancelled: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Nov 1, 2022

    Passed: Building - Footer

    Inspected by Matt Forsyth

  4. Nov 1, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  5. Nov 23, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  6. Nov 29, 2022

    Failed: Building - Slab

    Perimeter Rebar Was Cut Out Where Shower Form Is Need Five Bar With Lap On Both Sides

    Inspected by Matt Forsyth

  7. Nov 30, 2022

    Passed: Building - Slab

    Item Addressed

    Inspected by Matt Forsyth

  8. Dec 1, 2022

    Cancelled: Building - Slab

    Inspected by Matt Forsyth

  9. Dec 13, 2022

    Passed: Building - Roof Decking

    Any Exposed Nails Need To Be Removed

    Inspected by Matt Forsyth

  10. Dec 13, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  11. Dec 13, 2022

    Passed: Building - Wall Sheathing

    Any Exposed Nails Need To Be Removed

    Inspected by Matt Forsyth

  12. Jan 5, 2023

    Passed: Building - Insulation

    Walls Only

    Inspected by Matt Forsyth

  13. Jan 5, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  14. Jan 5, 2023

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  15. Jan 5, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  16. Jan 24, 2023

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  17. Jan 24, 2023

    Release to power company

    Inspected by Matt Forsyth

  18. Mar 31, 2023

    Passed: Electrical - Permanent Power

    Need Septic And Driveway Releases

    Inspected by Matt Forsyth

  19. Apr 11, 2023

    Septic Release Inspection

    Need Drive Release

    Inspected by Health Dept

  20. Apr 17, 2023

    Release to power company

    Inspected by Melissa Garber

  21. May 19, 2023

    Failed: Building - Pre-Certificate Public Works Inspection

    Miter End Need Repair Of Erosion At Miter And Under Driveway.

    Inspected by Troy Crews

  22. May 19, 2023

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents