Permit Details

Permit Search

Permit

Roof Replacement or Repair

1172 SW FAIRFAX GLN
LAKE CITY, FL 32025

Permit #
000045695
Application #
56774
Status Completed
  1. Submitted Oct 12, 2022
  2. Issued Oct 17, 2022
  3. Expires May 29, 2023
  4. Completed Nov 30, 2022

Property

Parcel #
08019-117
Owner
Maria Romack
Acres
0.13
Subdivision
Grandview Village Unit 1
Zoning
—
Flood zone
X
District
5

Permit

Status
Completed
Septic release
N/A
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0292D
Type Roofing Job
Overlay with Metal
Type of structure
House
Commercial or Residential
Residential
Roof Area (for this job) Sq Ft
1800
No. of Stories
1
Roof Pitch
4:12 or Greater
Is the existing roof being removed?
No
Type of New Roofing Product
Metal
Florida Product Approval Number
FL-17992.1 R3
Product Manufacturer
Capital Metal Supply
Product Description
Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16” OSB
Building Code Edition
2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation:
Ridge Vent
Flashing:
Use Existing
Drip Edge:
Replace All
Valley Treatment:
New Metal
Any cable and/or race-way wiring located on or within the roof assembly?
No

Status & Review History

  1. Application pending.
  2. Application submitted by applicant.
  3. City of Lake City
  4. Final Review - Documents Required
  5. Final Review - Payment Needed
  6. Permit Issued

Contractors

  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Contractor

Inspections

  1. Nov 18, 2022

    Failed: Re-Roof - In Progress

    No Work Being Done.

    Inspected by Troy Crews

  2. Nov 23, 2022

    Passed: Re-Roof - In Progress

    Inspected by Troy Crews

  3. Nov 30, 2022

    Passed: Re-Roof - Final

    Inspected by Troy Crews