Permit Details

Permit Search

Permit

New Residential Construction

235 SW JACKRABBIT CT
FORT WHITE, FL 32038

Permit #
000045522
Application #
55931
Status Completed
  1. Submitted Aug 8, 2022
  2. Issued Feb 21, 2023
  3. Expires Mar 25, 2024
  4. Completed Sep 27, 2023

Property

Parcel #
03816-317
Owner
Dahm James, Dahm Rosemarie S
Acres
10.02
Subdivision
Tustenuggee Trails Unr
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
91.50'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0485C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1892
Total Area (Sqft)
1955
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0648
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Corrections Needed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Fuel/Gas Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Final Review - Documents Required
  13. Final Review - Documents Required
  14. Final Review - Documents Required
  15. Final Review - Documents Required
  16. Final Review - Reviewed
  17. Final Review - Reviewed
  18. Permit Issued
  19. Plan Review - Reviewed
  20. Permit Reissued

Contractors

  • Roger Whiddon

    Whiddon Construction Co. Inc

    License
    CRC1328025
    Title
    Residential Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Roger Whiddon

    Lake City Plumbing Inc

    License
    CFC1428686
    Title
    Cert Plumbing
    Role
    Subcontractor
  • Roger D Whiddon

    Whiddon Construction Co Inc

    License
    CCC1330273
    Title
    Roofing Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • Matthew H Burns

    Burns Electrical Services Inc

    License
    EC13006531
    Title
    Electrical Contractor
    Role
    Subcontractor

    Workers Comp Expired.

Inspections

  1. Sep 26, 2022

    Passed: Electrical - Temporary Service

    Inspected by Matt Forsyth

  2. Sep 26, 2022

    Release to power company

    Inspected by Matt Forsyth

  3. Oct 14, 2022

    Release to power company

    Changed Power Company

    Inspected by Matt Forsyth

  4. Nov 21, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  5. Dec 13, 2022

    Passed: Building - Monolithic Slab

    Inspected by Anthony Aslan

  6. Dec 13, 2022

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  7. Dec 15, 2022

    Passed: Building - Monolithic Slab

    Send Termite Report

    Inspected by Troy Crews

  8. Dec 15, 2022

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  9. Jan 17, 2023

    Failed: Building - Monolithic Slab

    Elevation Confirmation Prior To Any Further Inspections

    Inspected by Troy Crews

  10. Jan 17, 2023

    Cancelled: Engineering - Setbacks

    Inspected by Troy Crews

  11. Feb 6, 2023

    Cancelled: Building - Strapping

    Inspected by Troy Crews

  12. Feb 6, 2023

    Passed: Building - Wall Sheathing

    Inspected by Troy Crews

  13. Feb 6, 2023

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  14. Feb 6, 2023

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  15. Feb 22, 2023

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  16. Feb 22, 2023

    Passed: Building - Framing

    Inspected by Troy Crews

  17. Feb 22, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Troy Crews

  18. Feb 22, 2023

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  19. Feb 22, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Troy Crews

  20. May 4, 2023

    Passed: Building - Insulation

    Inspected by Troy Crews

  21. Aug 23, 2023

    Septic Release Inspection

    Inspected by Health Dept

  22. Sep 11, 2023

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  23. Sep 11, 2023

    Release to power company

    Inspected by Troy Crews

  24. Sep 27, 2023

    Passed: Building - Final

    Inspected by Troy Crews

Documents