Permit Details

Permit Search

Permit

New Residential Construction

2263 SE OCTOBER RD
LAKE CITY, FL 32025

Permit #
000045421
Application #
55874
Status Completed
  1. Submitted Aug 18, 2022
  2. Issued Sep 19, 2022
  3. Expires Dec 18, 2023
  4. Completed Jun 22, 2023

Property

Parcel #
09651-000
Owner
King Brandon D, King Tonya M
Acres
14.70
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Engineers Elevation Letter
Finished floor requirement
72.50'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0505C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1964
Total Area (Sqft)
2807
Building Height
19
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0738
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Building Approved
  5. Plan Review - Electrical Approved
  6. Plan Review - Mechanical Approved
  7. Plan Review - Plumbing Approved
  8. Plan Review - Fuel/Gas Approved
  9. Zoning Review - Reviewed
  10. Plan Review - Reviewed
  11. Final Review - Documents Required
  12. Final Review - Documents Required
  13. Final Review - Documents Required
  14. Final Review - Documents Required
  15. Final Review - Reviewed
  16. Final Review - Payment Needed
  17. Permit Issued
  18. Permit Reissued
  19. Final Review - Payment Needed

Contractors

  • Isaiah Cully

    Ic Construction Llc

    License
    CBC1259655
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor

Inspections

  1. Oct 12, 2022

    Passed: Building - Footer

    Inspected by Anthony Aslan

  2. Oct 12, 2022

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  3. Nov 30, 2022

    Passed: Electrical - Temporary Service

    Inspected by Anthony Aslan

  4. Nov 30, 2022

    Release to power company

    Inspected by Anthony Aslan

  5. Dec 7, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  6. Dec 9, 2022

    Passed: Building - Slab

    Inspected by Anthony Aslan

  7. Jan 23, 2023

    Cancelled: Building - Framing

    Inspected by Anthony Aslan

  8. Feb 3, 2023

    Passed: Building - Roof Decking

    Next Time Need To See Before Wrap Or Will Have It Pulled Off To Inspect.

    Inspected by Anthony Aslan

  9. Feb 3, 2023

    Passed: Building - Ext Strapping/Wall Sheathing

    Next Time Need To See Before Wrap Or Will Have It Pulled Off To Inspect.

    Inspected by Anthony Aslan

  10. Feb 3, 2023

    Passed: Building - Framing

    Inspected by Anthony Aslan

  11. Feb 16, 2023

    Passed: Electrical - 2nd Rough-In

    Any Wall Section 2'ft Or Greater Requires An Outlet

    Inspected by Anthony Aslan

  12. Feb 16, 2023

    Failed: Mechanical - Rough In

    Master Bath Missing Exhaust Fan

    Inspected by Anthony Aslan

  13. Feb 16, 2023

    Failed: Plumbing/Gas - 2nd Rough-In

    Not Ready

    Inspected by Anthony Aslan

  14. Feb 17, 2023

    Cancelled: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  15. Feb 17, 2023

    Passed: Mechanical - Rough In

    Correction Made

    Inspected by Anthony Aslan

  16. Feb 17, 2023

    Failed: Plumbing/Gas - 2nd Rough-In

    Not Complete

    Inspected by Anthony Aslan

  17. Feb 17, 2023

    Cancelled: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  18. Feb 24, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  19. Feb 24, 2023

    Passed: Building - Insulation

    Inspected by Anthony Aslan

  20. Apr 17, 2023

    Septic Release Inspection

    Inspected by Health Dept

  21. May 31, 2023

    Passed: Electrical - Permanent Power

    Need Wire To Island Safety Off (recv'd)

    Inspected by Anthony Aslan

  22. Jun 13, 2023

    Release to power company

    Recv'd

    Inspected by Anthony Aslan

  23. Jun 16, 2023

    Failed: Building - Final

    Incomplete Multiple Items

    Inspected by Anthony Aslan

  24. Jun 21, 2023

    Passed: Building - Final

    Need Final Termite

    Inspected by Anthony Aslan

  25. Jun 22, 2023

    Certificate-Release Certificate

    Documents Uploaded

    Inspected by Anthony Aslan

Documents