Permit Details

Permit Search

Permit

New Residential Construction

1585 SW COUNTY ROAD 252B
LAKE CITY, FL 32024

Permit #
000045409
Application #
56116
Status Completed
  1. Submitted Aug 17, 2022
  2. Issued Sep 12, 2022
  3. Expires Mar 23, 2024
  4. Completed Sep 25, 2023

Property

Parcel #
02851-002
Owner
Thomas Steven Parker, Thomas Tracy Ynatte
Acres
3.45
Subdivision
—
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0290D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
1391
Total Area (Sqft)
2099
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0646
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. City of Lake City Utilities Notified
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Plan Review - Documents Required
  6. Plan Review - Building Approved
  7. Plan Review - Electrical Approved
  8. Plan Review - Mechanical Approved
  9. Plan Review - Plumbing Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Final Review - Documents Required
  13. Final Review - Reviewed
  14. Final Review - Payment Needed
  15. Permit Issued

Contractors

  • Sara E Gresham

    John Norris Construction, Llc

    License
    CRC1331978
    Title
    Cert. Residential
    Role
    Contractor
  • Don C Bills Sr

    Hometown Plumbing Services Llc

    License
    CFC1428890
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Mary C Johnson

    Rcra Johnson Roofing,inc.

    License
    CCC1330073
    Title
    Roofing Contractor
    Role
    Subcontractor
  • Donald R Hollingsworth

    Holly Electric Inc

    License
    EC13005429
    Title
    Electrical
    Role
    Subcontractor
  • Jan R Touchton

    Touchton's Heating & Air Conditioning Inc

    License
    CAC058747
    Title
    Cert. A/c Class “a”
    Role
    Subcontractor

Inspections

  1. Sep 23, 2022

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Sep 23, 2022

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Nov 3, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Waste Pipe Only

    Inspected by Matt Forsyth

  4. Nov 17, 2022

    Rescheduled 11/23/2022:Building - Slab

    Inspected by Matt Forsyth

  5. Nov 22, 2022

    Passed: Building - Slab

    Pictures Sent To Matt

    Inspected by Troy Crews

  6. Dec 14, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  7. Dec 14, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  8. Feb 1, 2023

    Passed: Building - Framing

    Inspected by Matt Forsyth

  9. Feb 1, 2023

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  10. Feb 1, 2023

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  11. Feb 1, 2023

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  12. Feb 1, 2023

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Tub Water Tested

    Inspected by Matt Forsyth

  13. Feb 10, 2023

    Passed: Building - Footer

    Inspected by Matt Forsyth

  14. Feb 10, 2023

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  15. Mar 3, 2023

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  16. Jun 15, 2023

    Septic Release Inspection

    Inspected by Health Dept

  17. Jun 29, 2023

    Passed: Electrical - Permanent Power

    Disconnect Needed For Air Conditioning Handler

    Inspected by Matt Forsyth

  18. Jun 29, 2023

    Release to power company

    Inspected by Matt Forsyth

  19. Sep 25, 2023

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents