Passed: Electrical - Permanent Power
-need Septic Release
-e3705.7location Of Overcurrent Devices In Or On Premises.
overcurrent Devices Shall:
1.be Readily Accessible. [240.24(a)]
2.not Be Located Where They Will Be Exposed To Physical Damage. [240.24(c)]
3.not Be Located Where They Will Be In The Vicinity Of Easily Ignitable Material Such As In Clothes Closets. [240.24(d)]
4.not Be Located In Bathrooms. [240.24(e)]
5.not Be Located Over Steps Of A Stairway.
6.be Installed So That The Center Of The Grip Of The Operating Handle Of The Switch Or Circuit Breaker, When In Its Highest Position, Is Not More Than 6 Feet 7 Inches (2007 Mm) Above The Floor Or Working Platform. [240.24(a)]
-e3705.8ready Access For Occupants.
each Occupant Shall Have Ready Access To All Overcurrent Devices Protecting The Conductors Supplying That Occupancy
-e3405.4outdoor Dedicated Panelboard Space.
the Outdoor Space Equal To The Width And Depth Of The Panelboard, And Extending From Grade To A Height Of 6 Feet (1.8 M) Above The Panelboard, Shall Be Dedicated To The Electrical Installation. Piping And Other Equipment Foreign To The Electrical Installation Shall Not Be Located In This Zone.