Permit Details

Permit Search

Permit

Modular Building - Residential or Commerical

195 SW KNIGHT TER
FORT WHITE, FL 32038

Permit #
000045190
Application #
54620
Status Completed
  1. Submitted May 3, 2022
  2. Issued Aug 16, 2022
  3. Expires Aug 2, 2023
  4. Completed Feb 9, 2023

Property

Parcel #
04238-005
Owner
Pender Dannette R, Pender Dan Eugene Micah
Acres
0.56
Subdivision
Hollingsworth Bluff
Zoning
ESA-2
Flood zone
AE
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Special Flood Hazard Area
Finished floor requirement
36'
Requirement needed
By Final Inspection
Document needed is
an Elevation Certificate for Finished Construction
Document receieved
Yes
Fema map number
12023C0526C
Water source
Sante Fe
In floodway
N
Modular frame type
On frame
Use Type:
Residential
Heated Area (Sqft)
1080
Total Area (Sqft)
1080
Stories
1
Service Amps
30
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Septic# (00-0000) or (X00-000)
22-0022
Dev Permit #
F023-22-008
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code

Status & Review History

  1. Application pending.
  2. Point Review - Processing
  3. Point Review - Printed-Online Application
  4. Point Review - Reviewed
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Documents Required
  9. Zoning Review - Reviewed
  10. Plan Review - Plumbing Approved
  11. Plan Review - Mechanical Approved
  12. Plan Review - Electrical Approved
  13. Plan Review - Building Approved
  14. Plan Review - Reviewed
  15. Final Review - Reviewed
  16. Final Review - Reviewed
  17. Application Converted
  18. Final Review - Payment Needed
  19. Permit Issued

Contractors

  • Leslie Weiss

    Hydra Engineering & Construction Llc

    License
    CGC1529351
    Title
    Cert. General
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Randy Collins

    C&r Electrical Services,inc.

    License
    EC13005730
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • James Plant

    Legacy Roofing And Construction Of Nfl Inc

    License
    CCC1333244
    Title
    Cert. Roofing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Arthur D Scott

    Dave Scott's Heating And Air

    License
    CAC1814204
    Title
    Cert. A/c Class “a”
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Daniel Waskom

    Williston Services Plumbing Dba All American Plumbing

    License
    CFC1430925
    Title
    Cert. Plumbing
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Nov 3, 2022

    Passed: Engineering - Setbacks

    Tight Lot Setbacks Need Surveyor Verification

    Inspected by Anthony Aslan

  2. Nov 3, 2022

    Passed: Building - Footer

    Clean Out Footings Where Needed

    Inspected by Anthony Aslan

  3. Nov 8, 2022

    Passed: Building - Lintel/Tie Beam

    Inspected by Anthony Aslan

  4. Dec 20, 2022

    Passed: Electrical - Permanent Power

    Need Elevation Certificate , Need Spetic Release

    Inspected by Anthony Aslan

  5. Dec 27, 2022

    Failed: Electrical - Permanent Power

    Received Elevation Certificate And Electric Meter Is Below Required One Foot Above Base Flood Elevation. Need To Raise And Have Elevation Certificate Revised.

    Inspected by Troy Crews

  6. Jan 9, 2023

    Cancelled: Modular - Strapping

    Inspected by Troy Crews

  7. Jan 9, 2023

    Cancelled: Electrical - Temporary Service

    Inspected by Troy Crews

  8. Jan 17, 2023

    Failed: Modular - Strapping

    Need New Elevation Certificate To Include Power Meter Being Raised. Prior To Permanent Power-- Elevation Certificate Rec'd-- Electric Meter Still Below Mfe

    Inspected by Troy Crews

  9. Jan 20, 2023

    Cancelled: Modular - Strapping

    Inspected by Emaleigh Williams

  10. Jan 25, 2023

    Passed: Electrical - Permanent Power

    -need Septic Release -e3705.7location Of Overcurrent Devices In Or On Premises. overcurrent Devices Shall: 1.be Readily Accessible. [240.24(a)] 2.not Be Located Where They Will Be Exposed To Physical Damage. [240.24(c)] 3.not Be Located Where They Will Be In The Vicinity Of Easily Ignitable Material Such As In Clothes Closets. [240.24(d)] 4.not Be Located In Bathrooms. [240.24(e)] 5.not Be Located Over Steps Of A Stairway. 6.be Installed So That The Center Of The Grip Of The Operating Handle Of The Switch Or Circuit Breaker, When In Its Highest Position, Is Not More Than 6 Feet 7 Inches (2007 Mm) Above The Floor Or Working Platform. [240.24(a)] -e3705.8ready Access For Occupants. each Occupant Shall Have Ready Access To All Overcurrent Devices Protecting The Conductors Supplying That Occupancy -e3405.4outdoor Dedicated Panelboard Space. the Outdoor Space Equal To The Width And Depth Of The Panelboard, And Extending From Grade To A Height Of 6 Feet (1.8 M) Above The Panelboard, Shall Be Dedicated To The Electrical Installation. Piping And Other Equipment Foreign To The Electrical Installation Shall Not Be Located In This Zone.

    Inspected by Anthony Aslan

  11. Jan 26, 2023

    Release to power company

    Inspected by Melissa Garber

  12. Jan 26, 2023

    Septic Release Inspection

    Inspected by Health Dept

  13. Jan 31, 2023

    Failed: Building - Final

    -dryer Vent Must Be Smooth Pipe -under Pinning Needs To Be Taped Up -platform For Panel Is Incorrect, No Handrails And About 2'ft Away From Panel -some Out Riggers On Frame Cut -wedges On All Piers Are Not Installed Correctly, Not Touching Or Overlapping Each Other -no Hand Rails On Stairs

    Inspected by Anthony Aslan

  14. Feb 3, 2023

    Passed: Building - Final

    *the Dryer Pipe Crimped Is Facing In The Direction Of Air Flow, Needs To Meet These Minimum Codes, Although It Is Smooth There Is No Gauge Stamped On The Aluminum Pipe. If You Can Provide Manufacture Specs On Pipe That Meet The Minimum Code Requirements. sectionm1502 clothes Dryer Exhaust m1502.4dryer Exhaust Ducts. dryer Exhaust Ducts Shall Conform To The Requirements Of Sections M1502.4.1 Through M1502.4.7. m1502.4.1material And Size. exhaust Ducts Shall Have A Smooth Interior Finish And Be Constructed Of Metal Having A Minimum Thickness Of 0.0157 Inch (28 Gauge). The Duct Shall Be 4 Inches (102 Mm) Nominal In Diameter. exception: Exhaust Ducts May Be 4 Inches Nominal In Diameter Schedule 40 Pvc When Horizontally Run Beneath The Slab. m1502.4.2duct Installation. exhaust Ducts Shall Be Supported At Intervals Not To Exceed 12 Feet (3658 Mm) And Shall Be Secured In Place. The Insert End Of The Duct Shall Extend Into The Adjoining Duct Or Fitting In The Direction Of Airflow. Exhaust Duct Joints Shall Be Sealed In Accordance With Section M1601.4.1. Ducts Shall Not Be Joined With Screws Or Similar Fasteners. Where Dryer Exhaust Ducts Are Enclosed In Wall Or Ceiling Cavities, Such Cavities Shall Allow The Installation Of The Duct Without Deformation.

    Inspected by Anthony Aslan

  15. Feb 9, 2023

    Certificate-Release Certificate

    Contractor Needs To Get State Final Inspection Results.

    Inspected by Anthony Aslan

Documents